Visual Inspection and Cleaning:
1.
Switch off the unit, unplug the power cord from the electrical socket.
2.
For filter pumps with 32mm (1-1/4”) hose size - To prevent water from
escaping the pool, unscrew the strainer grids from the strainer connectors and
insert the hat-like plugs into the strainer connectors.
For filter pumps with 38mm (1-1/2”) hose size - Grasp a plunger valve
handle. Turn the handle counter-clockwise, push down until it stops and then
turn it clockwise until the plastic protruding notch anchors in the "0/I" position.
Repeat for the 2nd plunger valve. This prevents the water from flowing out of
the pool.
3.
Disconnect screen fitting (10) from the flow sensor conduit (6). See “Parts
Reference”.
4.
Disconnect the adaptor A from the Saltwater System outlet. Look inside the
electrolytic cell (4) inspect for scale formation (light colored crusty or flaky
deposits) on the titanium plates. If no deposits and debris are visible reinstall
the adaptor A (1), and screen fitting (10).
5.
If deposits and debris are seen on the titanium plates, use a high pressure
garden hose and try to flush them off. Only flush from the direction of water
inlet to avoid damaging the flow sensor. Do not use any metal tool as this will
scratch the coating off the plates. Note that a buildup on the cell indicates that
there is an unusually high calcium level in the pool. If this is not corrected, you
have to frequently check and clean the cell. To avoid this, always keep your
pool chemistry at the recommended levels. See “Pool Maintenance & Chemical
Definitions” for reference.