Intex Hydro Flow SM24101 Owner'S Manual Download Page 6

(303PO)  MODEL SM24101 SWIMMING MACHINE  ENGLISH  7.5” X 10.3”  PANTONE 295U  02/21/2017

303

PO

    

SAVE THESE INSTRUCTIONS

English

Page 6

•  Pool must be 

fi

 lled with water prior to installation. Two adults required.

• 

Tools required:

 one Philip screwdriver, one 

fl

 at screwdriver and one small adjustable 

 wrench.

•  Pool size requirements:

  Pool water depth: 100cm (39 inch) minimum. 

  Pool length: 4.6m (15') minimum.  

  Pool width: 2.5m (8.2') minimum.

Transformer Location Requirement
1. 

The transformer must be installed on a solid level and vibration-free area. 

2.

 Provide a location protected from the weather, moisture, rain, splashing water, 

fl

 ooding 

  and freezing temperature.

3.

 Provide adequate access, space and lighting for routine maintenance.

4.

 The transformer requires free circulation of air for cooling.

Swim-Trainer Unit and Support Bracket Assembly, for all type of pools.

NOTE: Make sure the pool wall is able to support a load of 25 kg (55 Lbs) or more 
before installation.

Model:

 SM24101

Voltage:

 

Transformer input 110-120V AC / 60Hz 8A 

   

Transformer output 24V DC 35A

Suitable for: 

 

In ground pool or Intex above ground metal frame pools

Pool water temperature range:

  25ºC - 35ºC

* Approximate

PRODUCT SPECIFICATIONS

SETUP INSTRUCTIONS 

Speed Setting*

1

2

3

4

5

6

7

8

m/s

0.66

0.77

0.83

0.94

0.98

1.06

1.16

1.21

ft/s

2.17

2.53 2.72 3.08 3.22 3.48 3.81

3.97

This device generates a constant flow of pool water that allows the user to swim 
uninterrupted in the swimming pool.

25

20

24

22

Summary of Contents for Hydro Flow SM24101

Page 1: ...ories or to obtain non technical assistance Visit www intexcorp com For technical assistance and missing parts call us toll free for U S and Canadian Residents 1 800 234 6839 Monday through Friday 8 3...

Page 2: ...Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generat...

Page 3: ...mers and other equipment To reduce the risk of electric shock replace damaged cord immediately Use a qualified electrician to replace the cord To reduce the risk of electric shock do not use extension...

Page 4: ...Bracket NOTE Drawings for illustration purpose only Actual product may vary Not to scale REF NO DESCRIPTION QTY IGP POOL Intex Rectangular Frame Pool Intex Round Frame Pool SPARE PART NO 1 Mounting Br...

Page 5: ...control 1 12381 12381 12381 19 Emergency stop lanyard 1 12374 12374 12374 20 Clamp knob 2 12395 12395 12395 21 Circuitry box 1 12387 12387 12387 22 Support bracket 1 12398 12398 12398 23 Support plate...

Page 6: ...zing temperature 3 Provide adequate access space and lighting for routine maintenance 4 The transformer requires free circulation of air for cooling Swim Trainer Unit and Support Bracket Assembly for...

Page 7: ...nting Bracket Assembly A For Intex Rectangular Frame Pools 1 Mounting Bracket Assembly see figures 1 1 to 1 2 NOTE Center the swim trainer unit on the short end side of the pool 2 Installing the mount...

Page 8: ...acket top surface is level 3 Swim Trainer Unit Assembly see figures 3 1 to 3 2 Be sure the swim trainer unit support bracket is closed before installing the swim trainer unit onto the mounting bracket...

Page 9: ...ure 4 3 to 4 5 For shape pipe remove the bracket space filler 3 from the mounting bracket 2 see figure 4 2 For O shape pipe go to next step Insert the bracket poles 6 into the mounting bracket 2 inner...

Page 10: ...igure 5 2 For shape vertical leg pipe do not include the A B C gap filler 11 For 38mm diameter vertical leg pipe include A gap filler For 44mm diameter vertical leg pipe include B gap filler For 48mm...

Page 11: ...tention to the electrical gas and water lines when drilling the holes All screws provided must be used Drill two holes on the center of the short end side of the pool edge where the mounting bracket w...

Page 12: ...with only the top surface of the housing exposed Lock the nuts in place after the height of the swim trainer unit is adjusted see figure 7 2 Attach the display panel 16 onto the swim trainer unit moun...

Page 13: ...away from the pool so as to prevent children from climbing on it and accessing the pool 4 Test the GFCI or RCD before use a Press the RESET button The indicator on the RCD should be ON b Press the TE...

Page 14: ...ease or decrease the speed setting NOTE The default speed is 3 speed adjustment ranges from 1 to 8 D Speed Setting Display Once activated the system displays the swim trainer unit speed automatically...

Page 15: ...ver Long Term Storage and Winterization You must disassemble and store the product indoors when the temperature drops below 0O C 32O F or when the appliance will not be used for a long period of time...

Page 16: ...0 3 PANTONE 295U 02 21 2017 303 PO SAVE THESE INSTRUCTIONS English Page 16 INTERNAL PARTS REPLACEMENTS Tools required one Philip screwdriver one flat screwdriver and one small adjustable wrench A Prop...

Page 17: ...MING MACHINE ENGLISH 7 5 X 10 3 PANTONE 295U 02 21 2017 303 PO SAVE THESE INSTRUCTIONS English Page 17 INTERNAL PARTS REPLACEMENTS continued B Swim trainer unit bracket and circuitry box disassembly 2...

Page 18: ...al Make sure the device is under the water It s normal Turn off the transformer for 1 minute then plug in Check the voltage is within the range stated on the device housing H Household voltage is too...

Page 19: ...e motor cool down and restart again No LED display The transformer is unplugged or off The transformer is not connected with swim trainer unit Display panel cord is loose Display panel failure Emergen...

Page 20: ...ll disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no...

Reviews: