61
Error
Cause
Remedy
Display failure
-
Display crashed – i.e. by
voltage surge in power supply
(lightning) or electrostatic
discharge
Note:
The program runs
normally in the background.
-
Restore the display function by
RESET (adjusted parameters
are lost) or disconnect the cable
bridge (s. section 6.1) on control
board.
Storage time exceeded
Note: Flashing LCD and audible signal
ON/OFF (1 sec. / 1sec.)
-
The water in the bioreactor has
not been filtered for at least 21
days (no filtration process has
been started within this time)
-
Check the greywater inlet flow
-
Repeat the start –up phase of the
bioreactor (s. section 9.2)
Power failure
Note: Flashing LCD and audible signal
ON/OFF (1 sec. / 1sec.)
-
power failure for more than 2
hours
(Biological treatment could be
affected when the failure
duration is more than 1 day!)
-
If power failure is less than 1 day
please confirm with NEXT
-
If a power failure occurred for more
than 1 day please repeat the start –
up phase of the bioreactor (s.
section 9.2)
Aeration failure
Note: Flashing LCD and audible signal
ON/OFF (1 sec. / 1sec.)
-
Working pressure of the blower
is too low
(Biological treatment could be
affected when the failure
duration is more than 1 day!)
-
Water level in the bioreactor
too low < 30cm
-
Check the blower, replace if
necessary
-
If a power failure occurred for more
than 1 day repeat the start –up
phase of the bioreactor (s. section
9.2)
Optional if the pressure
sensor mounted:
Failure backwash pump
Note: Flashing LCD and audible signal
ON/OFF (1 sec. / 1sec.)
-
For 4 pump cycles, backwash
pressure > 0.1 bar was detected
(normal 0.3-0.5 bar).
-
Check the backwash pump in test
menu
-
If a pump failure occurred, clean
the pump in case of blockage or
replace the pump.
Informative: Maximum level
of the bioreactor
-
Floating switch detected the
maximum level in the
bioreactor (only if the floating
-
Only informative, alarm has to be
confirmed manually
Summary of Contents for AQUALOOP GW 10800
Page 12: ...11 Fig AQUALOOP System 1200 L day 317 GPD Fig AQUALOOP System 1800 L day 476 GPD...
Page 13: ...12 Fig AQUALOOP System 3600 L day 952GPD Fig AQUALOOP System 5400 L day 1428 GPD...
Page 37: ...36 Fig Electrical connection plan upper pump lower pump...
Page 39: ...38 Fig Control cabinet of multiple membrane station controller...
Page 42: ...41 7 1 3 Expansion membrane station controller Fig Control cabinet of expansion controller...
Page 89: ...88 Designed and provided by INTEWA GmbH or to be separately approved alternative...
Page 90: ...89 INTEWA GmbH Version 1 1 a Subject to technical changes...