2.5 Overview AQUALOOP GW Systems 300 – 5400 L/day
AQUALOOP System GW
0300 0600 0900 1200L 1500
1800
3600
5400
Daily treatment quantity (L/day) *
300
600
900
1200
1500
1800
3600
5400
Daily Treatment Quantity (GPD)*
79
159
238
317
397
476
952
1428
Bioreactor net volume V
BR,use
(L) **
150-
300
300-
600
450-
900
600-
1200
750-
1500
900-
1800
1800-
3600
2700-
5400
Al-MS: Membrane station (pcs.)
1
1
1
1
1
1
2
3
Al-MEM: Membrane cartridge (pcs.)
1
2
3
4
5
6
12
18
PR-M:
Pre-filter (DN)
100
100
100
150
150
150
150
150
AL-FK: Growth bodies (L)
30
60
90
120
150
180
360
540
AL-BL: Blower
AL-
BL100
AL-
BL100
AL-
BL120
AL-BL120 AL-BL200 AL-BL200 2 x AL-
BL200
3 x AL-
BL200
VIP130-6: Sludge pump
1
1
1
1
1
1
1
1
* minimum average daily greywater yield and demand
** VBR,use = VBR,max - VBR,min
Tab.: System specifications for the certified AQUALOOP GW systems
Fig.: AQUALOOP System 300/600 L/day (79/159 GPD) (with one /two equipped membrane cartridge)
Summary of Contents for AQUALOOP GW 10800
Page 12: ...11 Fig AQUALOOP System 1200 L day 317 GPD Fig AQUALOOP System 1800 L day 476 GPD...
Page 13: ...12 Fig AQUALOOP System 3600 L day 952GPD Fig AQUALOOP System 5400 L day 1428 GPD...
Page 37: ...36 Fig Electrical connection plan upper pump lower pump...
Page 39: ...38 Fig Control cabinet of multiple membrane station controller...
Page 42: ...41 7 1 3 Expansion membrane station controller Fig Control cabinet of expansion controller...
Page 89: ...88 Designed and provided by INTEWA GmbH or to be separately approved alternative...
Page 90: ...89 INTEWA GmbH Version 1 1 a Subject to technical changes...