background image

2

 

 

 

WARNING: TO REDUCE THE RISK 

ELECTRIC SHOCK, DO NOT USE ON WET SURFACES 

 

1. 

Unplug from electrical outlet when not in use and before 

servicing. 

2. 

Do not use on wet surfaces. 

3. 

Never operate this vacuum cleaner without a dust bag and filters 

in place. 

4. 

Close attention is necessary when used by or near children. 

Do not allow unit to be used as a toy. 

5. 

Use only for intended use as described in this manual. Use only 

the manufacturer's recommended attachments and dust bag. 

6. 

Do not use with damaged cord or plug. If appliance is not working 

as it should, has been dropped, damaged, left outdoors, or fell into 

water, return the vacuum cleaner  to InterVac or an authorized 

service dealer for examination and repair. 

7. 

Do not put any object into openings.  Do not use with any openings 

blocked; keep free of dust, lint, hair, and any other material that 

may reduce air flow.  If the secondary filter becomes dirty, 

rinse in warm water or replace with a new filter. Filter should be 

completely dry before using. 

8. 

Never drop or insert any object into any opening. 

9. 

Turn off all controls before unplugging. 

10. 

Do not pull or carry by cord, do not use cord as a handle, do not 

close a door on the cord, or pull cord around sharp edges or 

corners.  Do not run over cord. Keep cord away from 

heated surfaces. 

 

11. 

Do not unplug by pulling on cord.  To unplug, grasp the plug, not 

the cord. 

12. 

Keep hair, loose clothing, fingers, and all parts of body away 

from any openings and all moving parts. 

13. 

Do not pick up anything that is burning or smoking, such as 

cigarettes, matches, or hot ashes. 

14. 

Use extra caution when cleaning on stairs. 

15. 

Do not handle plug or appliance with wet hands. 

16. 

Do not pick up flammable or combustible liquids such as 

gasoline or use in areas where they may be present. 

17. 

Do not place objects against the vacuum cleaner. Keep area 

clear. 

18. 

Do not step on the hose or pull the hose forcibly. 

19. 

Do not pick up large objects such as wastepaper or cloth, 

which may clog the hose. 

20. 

Do not install this vacuum cleaner in an area exposed to high 

temperatures. 

21. 

Install this vacuum cleaner in a dry place. 

22. 

Do not attempt to service the vacuum cleaner.  Unit is sealed 

and cannot be opened without damage to the unit.  For service, 

call your local authorized service dealer, or InterVac Design's 

Customer Care Center. 

SAVE THESE INSTRUCTIONS 

FOR HOUSEHOLD USE

 

Polarization  Instructions  for models  with  120volt  cord only. 

These  appliances  have  a polarized plug (one blade is wider than the other). 

This plug  will fit in a 

polarized outlet only one  way.  If  the plug  does not fit  fully in  the outlet, reverse  the plug. If  it still does not 

fit, contact a qualified electrician to install the proper outlet. Do not  change the  plug  in any way. 

When using an electrical vacuum cleaner, basic precautions should always be followed including the following: 

Read all instructions carefully before using this vacuum cleaner

 

LIMITED WARRANTY 

InterVac Design Corp. will repair the power unit with new or rebuilt parts, free of charge for three (3) years in North America 

from the date of original purchase in the event of a defect in materials or workmanship. Warranty might vary from country to 

country. No cash refunds. Excluded are the following items that require normal replacement: 

Disposable dust bags, filters, vacuum cleaner tools, and vacuum hoses. 

This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of original purchase will be 

required before warranty performance is rendered. 

You must return your warranty card or register on our website to be covered under these provisions

This warranty only covers failures due to defects in materials or workmanship which occurs during normal use and does not 

cover damage which occurs in shipment or failures which are caused by products not supplied by InterVac Design, or failures 

which result from accident, misuse, abuse, neglect, mishandling, misapplication, alteration, modification, or commercial use 

such as hotel, office, restaurant or rental use of the product, or service by anyone other than an authorized service center, or 

damage that is attributable to acts of God. 

There are no expressed warranties except as listed above. 

LIMITS AND EXCLUSIONS

INTERVAC DESIGN SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM 

THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY.  ALL EXPRESSED AND 

IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE, ARE LIMITED TO THE APPLICABLE WARRANTY PERIOD SET FORTHABOVE. 

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an 

implied warranty lasts, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights 

that vary from state to state. If a problem with this product develops during or after the warranty period, you may contact your 

dealer or our service center.  If the problem is not handled to your satisfaction, then write to the Customer Service Center at the 

company address. 

IMPORTANT SAFETY INSTRUCTIONS 

Summary of Contents for IVD660-F

Page 1: ...ch the dust bag properly and the filter under the bag in the correct position See page 10 MODEL IVD 660 H SURFACE MOUNTED with side panels IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH...

Page 2: ...wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to in...

Page 3: ...s second opening Secure with the four screws supplied Take the fitting and with the O ring side of the fitting first insert into the hole inside the top of the vacuum chamber 5 Hang the vacuum on to t...

Page 4: ...as Vaseline to the O ring on the flanged fitting K 382 Take the fitting with the O ring side up insert into the hole inside the top of the vacuum chamber towards the pipe NOTE You may have to jiggle t...

Page 5: ...for the cut out 6 Carefully cut the opening for the vacuum the width should be 9 1 4 and the height 18 1 4 7 Take one of the plywood strips and attach the double sticking tape to the wood 8 Carefully...

Page 6: ...g to the hole in the mounting frame Not available at this time Vacuum with junction box installed Romex cable to junction box Attaching flanged fitting K 382 for piped system and K 383 for stand alone...

Page 7: ...E PANEL K 340 TRACK FOR LOW VOLTAGE WIRE MOUNTING BRACKET SIDE PANEL WITH RUBBER PADS K 340 side panels left and right side are attached Remove side panels by loosening the 4 screws inside the vacuum...

Page 8: ...ket 115 16 Model IVD 660H surface mounted Model IVD 660H surface mounted InterVac Design Corp Palm City Florida 3 7 2019 patent pending UTILITY VALVE IN OPEN POSITION STEEL MOUNTING BRACKET ON OFF SWI...

Page 9: ...he hose at the POWER UNIT 1 Lift the inlet utility valve cover on the front of the door 2 Insert hose cuff with a twist and push to secure 3 To remove with one hand hold the door in place and with the...

Page 10: ...inserted with the cut out into the same area see to it that the filter is all the way pushed under the vertical ribs E Closing the Door 1 Take the door and open the utility valve cover 2 Lift the door...

Page 11: ...T X403 2 Part Upholstery Tool PART X300 Crevice Tool PART X200 OPTIONAL VACUUM TOOLS 35 Stretch Hose for quick clean up PART AS11 Elongated Dust Brush PART X251 Air Turbo Nozzle PART X451 Dust Sweeper...

Page 12: ...vacuum close to the garage door This way cars can be reached inside and outside the garage Most effective installation Minimal wall space other InterVac Models Model RMH 120 Installed as a traditional...

Page 13: ......

Reviews: