Operating and installation instructions

Operating and installation instructions

 Installer information

Installer information

E.

F.

R75

45°

45°

45°

45°

G.

• Vent-Axia wall kits and external grilles are available 

as accessories. (Figure E). 

H.

I.

R75

30°

65°

95°

J.

Always use a qualified electrician

All electrical connections 100-240V must be perfor-

med by a qualified electrician. Any electrical work on 

the product must utilise a  voltage break.

Electrical connection can be made according to the 

wiring diagram on page 8-9 and the fan is suitable 

for connection to either 100-240VAc or 12VDC.

NOTE: 

The internal cable route must  be as indica-

ted as figures K/K1 (240VAC) and L (12VDC) to 

prevent the cable blocking the locator’s for the motor 

assembly.

 

• Mark the three attachment points for the appro-

priate screws to the substrate (Figure J).

  Tighten the screws so that gasket seals against the 

wall.

  The fan’s wall seal has a short spigot which fits inside 

the Ø100 mm pipe. Make sure when mounting to 

adapt the length of the wall pipe so it does not push 

back the wall seal so the fan impeller cannot rotate. 

Always customise a wall pipe, existing or new, so 

it ends about 5 mm inside the wall surface where 

the fan is to be installed. The wall frame with its seal 

is prepared with 5 cable entry points (Figure F) for 

concealed electrical connection or surface-mounted 

cable using the dimension shown in Figure G. 

• Make sure that the gasket is properly installed on 

the wall frame, place it in the appropriate place 

and centre it in the pipe. 

  The wall frame can be offset horizontally by 

placing a spirit level on its support points 

  (Figure H and I).