background image

8

9

Operating and installation instructions

Installer information

Mounting the cover on the wall frame

• The fan is double insulated and must not be earthed. When the electrical connection is made place the 

cover back over the wall frame fitted into the housing hole (Figure P).

Q.

R.

P.

0

1

0

1

T.

S.

• Next, fold the cover over the wall frame (Figure Q). 
• Ensure the catch the screwdriver is pointing to (Figure R) engages properly.
• Make sure that the cover is firmly seated in the hook on the wall frame and latch by pulling a bit of cover.
• Finally put the motor unit in place (Figure S). Be careful when fitting motor unit, the impellor can be 

damaged if the unit is forced in at an angle. 

• A distinct ’click’ sound confirms that the device is in place, check that the integrated On switch works 

freely before turning on according to (Figure T). 

Operating and installation instructions

For the user  

Default setting:

Vent-Axia Svara is programmed to cope with the 

vast majority of installations.

The fan works continuously at a trickle flow of 

10l/s.

When the fan senses somebody in the room it 

increases the flow to 16l/s.

If the humidity rises rapidly, for example when 

the shower is on, the fan goes up to maximum 

flow at 30l/s.

When the fan senses the humidity level has 

returned to normal it reverts to the trickle flow of 

10l/s.

If other settings or functions are desired, down-

load the Vent-Axia Connect App from the App 

Store and Google Play.

 

Technical requirements for Vent-Axia 

Connect App

Apple devices iOS 7 or Android OS 4.3 or later 

with support for Bluetooth 4.

Fault indication:

Red LED on the fan indicates power failure when 

the calendar function has been activated.

Vent-Axia Svara

®

Automatic functions and settings via app

Activate the app:

You have to use a code to activate the app, the 

code is unique for each fan. Enter the code or 

scan it through your phone. 

Your unique code is on 

the back of the user guide and on the right leg of 
the motor unit (Figure T).

T.

Learn more about all the possibilities with 
our app at www.vent-axia.com/svara

Reviews: