Installation Preparation

• Loosen the motor unit by grasping it as shown in 

Figure (A), prise off the motor unit by leavera-

ging against the cap with your knuckles. Ensure 

that you have the motor unit in a secure grip so 

you do not drop it when it loosens.

• Then loosen the wall frame by using a screw–

  driver pressing the lock button as shown in 

Figure (B) then remove the cover from the wall 

frame according to figure (C).

Installation

A.

B.

C

DO NOT

 

install this product in areas where the 

following may be present or occur:

• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or 

vapours.

• Ambient temperatures are outside 5-50°C.
• Possible obstructions which would hinder the 

access or removal of the Fan.

SAFETY AND GUIDANCE NOTES

A. All wiring to be in accordance with the current 

I.E.E. Regulations, or the appropriate standards 

of your country and 

MUST

 be installed by a 

suitably qualified person.

B. The Fan should be provided with a local isola-

tor switch capable of disconnecting all poles, 

having a contact separation of at least 3mm.

C. Ensure that the mains supply (Voltage, 

  Frequency, and Phase) complies with the rating 

label.

D. The Fan should only be used in conjunction 

with the appropriate Vent-Axia products.

E. The fan should only be used in conjunction with 

fixed wiring.

F. When the Fan is used to remove air from a 

room containing a fuel-burning appliance, 

ensure that the air replacement is adequate for 

both the fan and the fuel-burning appliance.

G. The Fan should not be used where it is liable to 

be subject to direct water spray for prolonged 

periods of time.

H. Where ducted Fans are used to handle 

moisture-laden air, a condensation trap should 

be fitted. Horizontal ducts should be arranged 

to slope slightly downwards away from the Fan.

I. This appliance is not intended for use by young 

children or infirm persons without supervision.

J. Young children should be supervised to ensure 

that they do not play with the appliance.

K. The exterior grille should be at least 2.3m 

above the ground to prevent people from being 

able to access moving parts. If the external 

grille is positioned between 0-2.3m from the 

ground, please use the Vent-Axia wall kit to 

ensure people cannot access the fans impeller 

from the outside.

New Installations

New installations require holes using a Ø110 mm 

hole saw (Figure D).