MODELS:  SLM100/SLM80

Page 1.

INSTALLATION AND OPERATING INSTRUCTIONS

CEILING/WALL VENTILATION FAN

READ AND SAVE THESE INSTRUCTIONS

GENERAL SAFETY INFORMATION

1.

Make sure that the electric service supply voltage is AC 120V, 

60Hz.

 

2.

Follow all local electrical and safety codes, as well as the Nation 
Electrical Code (NEC) and the Occupation Safety and Healthy Act 

(OSH Act).

 

3.

Always disconnect the power source before working on or near
the ventilating fan, motor or junction box.

 

4.

Protect the power cord from sharp edges, oil, grease, hot 

surfaces, chemicals or other objects.

 

5.

Do not kink the power cord.

 

6.

Do not install the unit where ducts are con

ed as shown in 

Fig. A.

 

7.

Provide suction parts with proper ventilation.

 

8.

This unit is UL listed for use over a bathtub or shower when 

installed in a GFCI protected branch circuit.

 

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.

Use this unit only in the manner intended by the manufacturer. 
If you have questions, contact the manufacturer.

 

2.

Before servicing or cleaning unit, switch power

at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

 

3.

Installation work and electrical wiring must be done by qu

person(s) in accordance with all applicable codes and standards, 

 

4.

nt air is needed for proper combustion and exhausting of 

gases through

ue (chimney) of fuel burning equipment to 

prevent back drafting. Follow the heating equipment 
manufacturer's guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE), and the local code authorities.

 

5.

When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

 

6.

Ducted fans must always be vented to the outdoors.

 

7.

If this unit is to be installed over a tub or shower, it must be 
marked as appropriate for the application and be connected to

a GFCI (Ground Fault Circuit Interrupter) - protected branch 

circuit.

 

8.

Do not use this unit with any other solid-state control devices. 
Solid-state control devices may cause harmonic distortion, 

which can cause a motor humming noise.

 

9.

NEVER place a switch where it can be reached from a tub or

shower.

 

10. Not to be installed in a ceiling thermally insulated to a value 

greater than R50. (This is required for installation in Canada 

only).

 

CAUTION

1.

For General Ventilating Use Only. Do Not Use To Exhaust 
Hazardous Or Explosive Materials And Vapors.

 

2.

Not for use in cooking areas. (Fig. B)

 

3.

This product must properly connect to the grounding conductor 

of the supply circuit.

 

4.

To reduce the risk of injury to persons, install the fan at least 8.2 

fe

or. 

5016206300

45°

45°

floor

Fig. B

 

Cooking

Equipment

Cooking  area

Do not install above or

inside this area

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

 Body

Fig. A

Summary of Contents for breez Slim SLM100

Page 1: ...and standards 4 nt air is needed for proper combustion and exhausting of gases through ue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local ...

Page 2: ...h flange Screw M4x6 mm 1 Suspension Bracket 1 Joist Tabs Roof cap with built in damper Seal gap around housing Caulk termination to duct Fan housing Short piece of flexible duct helps alignment and absorbs sound or Wall cap damper Wall cap 2 3 ft straight run before elbow with built in 1 To bend the housing tabs out to 90 degree and make housing tabs contact the bottom or front of the joist 2 The ...

Page 3: ...cure fan body 1 Joist Joist Bottom Of Joist Ceiling Screw Ø4x25 mm Screw Ø4x25 mm Wall DUCT CONNECTION 1 Insert the duct into the duct connector and tape all ductworks connection to make them secure and air tight 2 Install the duct with a gradient 1 2 to the outside Inside Outside Duct Body Gradient 1 2 Grille Tape Ceiling Duct Connector Connection method for 3 round duct connector 3 4 oval to 3 r...

Page 4: ...transportation or storage improper testing improper installation improper operation improper use improper maintenance improper repair improper alteration improper modification tampering or accident of products or parts thereof or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products specifications Address 46101 Fremont B...

Reviews: