Transmitters and receivers 

no longer

 have to be directly linked to each other! 

We  recommend  this  specifically if  you  want  to  change  the  properties  of 
individual sensors according to the duration  of a scenario (e.g. all dimmers are 
capped to 50% brightness after 10 pm). 
 
After initial set up of the intertechno MasterGate, all transmitters and receivers 
in your smart home  are linked to the intertechno  hub, this means that you can 
digitally  and  dynamically  change  the  connection  between  transmitters  and 
receivers using the app. You can define scenarios or even change the function 
of  light  switches/remote  controls.  For  more  information,  see 

Adding 

transmitters/sensors

 

How do you tell if you're in configuration mode or user mode? 

 
As  mentioned  above,  we  strongly  advise  going  through  the  complete 
configuration mode at least once. Configuration mode is available only on your 
home network,  to which an intertechno  MasterGate must be connected.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Configuration  mode  allows you  to set up  your  smart home  to perfection.  We 
recommend  proceeding  one  step  at  a  time  by  first  connecting  and  pairing 
receivers.  We  suggest  that  you  first  get  familiar  with  the  intertechno 
MasterGate before moving on to setting up other  configurations. 
 
User  mode  allows you  to  control  your  smart  home  by  switching  individual 
receivers on/off or activating scenarios for example. This mode is not designed 
to be used to make changes to settings. 

Black background: 

User mode 

White background: 

Configuration mode 

Summary of Contents for MasterGate IT-MG

Page 1: ......

Page 2: ......

Page 3: ...S SENSORS OR WALL SWITCHES 12 ADVANCED SETTINGS CREATING IF THEN RELATIONSHIPS 12 ADVANCED SETTINGS PAIRING TRANSMITTER SENSORS WALL SWITCHES AND INFRARED EQUIPMENT 13 STEP 4 DEFINING SCENARIOS 14 DEF...

Page 4: ...i Fi router as well as an active internet connection Please make sure these connections are working otherwise server requests e g what time it gets dark will not be possible An active internet connect...

Page 5: ...Adding transmitters sensors How do you tell if you re in configuration mode or user mode As mentioned above we strongly advise going through the complete configuration mode at least once Configuratio...

Page 6: ...The intertechno MasterGate uses the 2 4 GHz frequency band The 5 GHz frequency band may cause interference so please deactivate this band if your router uses it How to proceed Connect the intertechno...

Page 7: ...find the serial number S N on the label on the bottom of your intertechno MasterGate Distinctions are made between S N 850 orV1 0 or S N 910 or higher or V2 0 or higher the following description appl...

Page 8: ...tiple users to use the configuration you created Reset Your intertechno MasterGate is reset to factory settings Step 3 Create default configuration configuration menu 6 The default configuration is di...

Page 9: ...ch were built in 1995 or after You can give any receiver any name and even choose from different icons Ensure that the name of the receiver does not contain any special characters or numbers as they a...

Page 10: ...lected from your smartphone gallery ATTENTION The icon will only be displayed on the respective local smartphone Remove photo The icon is removed and the previously selected icon is displayed Pairing...

Page 11: ...s the pairing button on your receiver and Pairing in the app Then test your smart home devices by clicking on ON or OFF Was the pairing successful Then touch the green box 15 If you have a receiver wi...

Page 12: ...ct or move cabinets e g ifyou want to modify connections Use transmitters sensors to trigger defined dimming values for receivers Have the option to create custom automatic power shut offs for receive...

Page 13: ...sensors wallswitches and infrared devices which you have previously set up 18 A progress display in percent will show how many receivers sensors are already paired 19 Click on the respective transmit...

Page 14: ...ial characters and numbers are not permitted as they create difficulties for voice command Defining basic moods 22 Select the receiver to be used for the basic mood Only previously selectedreceivers w...

Page 15: ...tion to match the duration of the scenario the transmitter sensor will behave according to the default configuration 24 Click on the transmitter sensor for which you want to match the property to the...

Page 16: ...background for this automation rule to be used The app must always have permission to perform its GPS queries Twilight A scenario can be activated at sunrise or sunset Time Day A scenario can be trig...

Page 17: ...turn red which means that the intertechno MasterGate app is waiting for a voice command Make sure the system volume is activated as the intertechno MasterGate app won t be able to speak back to you ot...

Page 18: ...to copy and paste into the Verification link field Make sure that you only copy the verification link and not the text above it 4 Click on Link Your Amazon account is now linked to your intertechno M...

Page 19: ...they would like to receive notifications for The PUSH notification will appear 1 3 minutes after the sensor has been triggered The intertechno MasterGate app must be active in the background for this...

Page 20: ...ntertechno MasterGate displayed in blue will inform you that the operation was completed successfully Your custom configuration will not be erased by a firmware update Step 11 Update summertime winter...

Page 21: ...30 60 seconds until the intertechno MasterGate is ready for operation otherwise Default configuration not transferred or update of default configuration not possible If applicable go to configuration...

Page 22: ...number of receivers that can be switched off using an automatic power shut off 10 Maximum number of receivers which can be switched on off by a scenario 20 Maximum number of delay modules in scenarios...