GUIDE  NOTES  (CUSTOMERS APPARATUS) 

NOT TO  BE SHOWN OUTSIDE  BRITISH TELECOM 

MINIMASTER 

SMALL ELECTRONIC SWITCHING SYSTEM 
FOR HOME OR OFFICE 

0018 

(1+6) 

British 

TEL.ECO�·\ 

TRAINING& 

EDUCATION 

DIVISION 

IDHQ/IT5.1.2 

ISSUE 

1  NOV.  1982 

Содержание MINIMASTER 1

Страница 1: ...CUSTOMERS APPARATUS NOT TO BE SHOWN OUTSIDE BRITISH TELECOM MINIMASTER 1 SMALL ELECTRONIC SWITCHING SYSTEM FOR HOME OR OFFICE 0018 1 6 British TEL ECO TRAININ G 1r 1 EDUCATION DIVISION IDHQ IT5 1 2 ISSUE 1 NOV 1982 ...

Страница 2: ......

Страница 3: ...ain maximum benefit from them they should be read completely by both Installation and Maintenance staff Contents Page 1 General Description 2 Installation 3 3 Setting Up the System 5 4 Facilities 8 5 Maintenance 11 Graphics and Typesetting by OPPUS V Shirley Solihull PRODUCED BY I DHQ IT5 1 2 2 NOVEMBER 1982 BRITISH TELECOMMUNICATIONS ...

Страница 4: ......

Страница 5: ... extensions b the expansion board which carries circuitry and terminal blocks for three additional extensions c the power unit which is connected to a 3 metre long mains cable with mains plug fused at 3 amps The telephones which are star connected to the CCU may be any standard telephone using loop disconnect pulsing Difficulty may be experienced in obtaining a satisfactory operation of the tone c...

Страница 6: ...Qlc 0 0 0b 0 0 0a 0 Cable Entry Slots Ql b Ql e 0e 0a Q d 0c 0b 0a 0d 0C 0b 0 a 0e 0e 0e 0e COVER FIXING SCREW MAINS CABLE TERMINAL BLOCK COVER FUSE HOLDER 500 ma anti surge fuse Fuse 36A 0 5 Exchange Line Extension 3 Extension 2 Extension 1 Recall earth Mains Cable NOTE Terminal blocks are a push fit on pins or t the printed circuit boards FIG 2 GENERAL ARRANGEMENT OF CCU ...

Страница 7: ... terminal blocks see fig 2 and check that the cable is correctly terminated with the green yellow conductor to Earth E terminal Wiring the brown conductor to Live L terminal the blue conductor to 240V terminal After checking the terminations of the mains cable replace the terminal block cover All cables enter the CCU via slots in the lower edge when mounted vertically of the back plate and are fed...

Страница 8: ...th six extensions it will be necessary to connect two extensions to the same earth terminal CABLING DISTANCES To ensure satisfactory operation of the system a the maximum loop resistance for an extension with earth loop recall is 60JJ This is equal to a 355 metre run of 0 5 mm copper cable b the maximum loop resistance for extensions where recall is not provided is 100D equivalent to a 595 metre r...

Страница 9: ...st Switches FIG 4 ARRANGEMENT OF FACILITY SWITCHES USE FINGERTIP TO GENTLY RELEASE OR OPERATE TH LATCH CLOSED OPERATED FIG 5 SAFETY PIN TYPE SWITCH Exist Switches Exist Switches Switches E 1 to E6 are used to open the extensions for use For an equipped extension the relevant E Switch must be open if an extension is not provided the E switch must be closed This is to ensure that the correct tone is...

Страница 10: ...tn 1 Extn 2 Extn 3 Extn 4 Extn 5 Extn 6 4 Extn 1 Extn 3 Extn 5 3 Extn 2 Extn 1 Extn 3 Extn 4 Extn 5 Extn 6 2 Extn 2 1 Extn 1 TABLE 1 Programmable ringing sequence Call Barring Switches A B and C2 to C6 are used with the Call Barring facility There is a choice of four options of barring with two groups of barring within each option Once an option has been selected it will apply to all extensions in...

Страница 11: ... v x x v v x x v v x x ISO v x v x v x v x v x OPTIONS Full ISD Access Barred Switch A Open Switch B Closed STD LOCAL v v v v v v v v v v v v v v v v v v v TABLE 2 CALL BARRING OPTIONS ISD x x x x x x x x x x ISD ISD Barred STD Barred Switch A Closed Switch B Open STD LOCAL v v x v v v x v v v x v v x _ _ x y ISO Full Barre Barring Switch A Closed Switch B Closed ISD STD LOCAL x v v x x x x v v x ...

Страница 12: ... exchange line calls c Receive incoming exchange line ringing d Answer incoming exchange line calls e Hold exchange line calls f Transfer exchange line calls g Conference calls on exchange line or intercom calls h Divert intercom calls Intercom Calls To make an intercom call lift the handset and listen for system dial tone If the intercom circuit is busy no dial tone will be heard On receipt of sy...

Страница 13: ...system ringing is connected to the extension according to the selected ringing programmes Any extension may answer the incoming call if the extension is ringing lift the handset the call is connected auto matically If the extension is not ringing lift the handset and dial digit 8 the call will then be connected to the extension Hold and Transfer An exchange Iine call may be held by either a dialli...

Страница 14: ...nder that transfer is still in effect To cancel divert the diverting extension lifts the handset dials digit 0 and then replace the handset Conference A conference call can be set up either between three extensions or two extensions and the exchange line To set up a conference an intercom enquiry call is made and the called extension invited to join the conference To join the conference the invite...

Страница 15: ... principal circuit board by means of a plug ended ribbon cable All line terminal blocks are connected to their respective circuit boards as push on connexions to printed circuit board pins The blocks may be prised off the circuit boards to save disconnecting the line and extension terminations when changing circuit boards The power supply must be switched off before the fuse is removed or replaced...

Страница 16: ...ly one containing electric motors or other inductive loads Central Control Units that have been maintenance exchanged should be carefully re packed using the packing of the replacement item Full fault details should be included out of ord er is not sufficient and if the item is within warranty period i e within 18 months of the date stamped on the back of the item it should be returned to the manu...