INTERTECHNO MasterGate IT-MG Instruction Manual Download Page 12

Advanced settings: Adding transmitters/sensors or wall switches 

 

 

Transmitters/sensors and wall switches can be added to your smart 

home, names can be given and IF-THEN relationships taught. 
 

(16)

 

To do so, touch           and enter a name. 

 

ATTENTION!  You  may  need  to  remove  any  pre-existing  direct 
pairings between transmitters and receivers,  as  communication 
will  now  take  place  using  the  intertechno  MasterGate,  and 
otherwise radio interference will occur.

 

 
 
The communication  principle  follows central intelligence. Add  any 
transmitters/sensors  or  wall  switches to  your  smart  home  if you 
want 

to: 

 

-

 

Use  the  app  in  the  future  to  make  direct  changes to  the 
connections  between  transmitters/sensors  and  receivers. 
Avoid having to reconnect or move cabinets, e.g. if you want 
to modify connections. 
 

-

 

Use  transmitters/sensors  to  trigger  defined  dimming  values  for 
receivers. 

 

-

 

Have  the  option  to  create  custom  automatic  power  shut-offs  for 
receivers in the app after triggering transmitters/sensors. 
 

-

 

The relationship between  transmitters/sensors and receivers and their 
characteristics may be modified for the duration  of scenarios,  
see 

Step 4: Defining scenarios

 (e.g. certain dimmers  are capped to 50% 

after 10 pm) 

 

Advanced settings: Creating IF-THEN relationships

  

 

In the next screen, you’ll be able to select which receivers should be switched 

on/off,  and/or  which  dimming  levels should  be set in  the  default 
configuration when transmitters/sensors are triggered. 
 

(17)

 

Click on the receiver or set the exact percentage for a 
dimmer  using the slider. 

 
You  can  also  program  it  to  turn  off  automatically  when 
transmitters/sensors are triggered, e.g. for a stairwell light. 

 
 
 

Summary of Contents for MasterGate IT-MG

Page 1: ......

Page 2: ......

Page 3: ...S SENSORS OR WALL SWITCHES 12 ADVANCED SETTINGS CREATING IF THEN RELATIONSHIPS 12 ADVANCED SETTINGS PAIRING TRANSMITTER SENSORS WALL SWITCHES AND INFRARED EQUIPMENT 13 STEP 4 DEFINING SCENARIOS 14 DEF...

Page 4: ...i Fi router as well as an active internet connection Please make sure these connections are working otherwise server requests e g what time it gets dark will not be possible An active internet connect...

Page 5: ...Adding transmitters sensors How do you tell if you re in configuration mode or user mode As mentioned above we strongly advise going through the complete configuration mode at least once Configuratio...

Page 6: ...The intertechno MasterGate uses the 2 4 GHz frequency band The 5 GHz frequency band may cause interference so please deactivate this band if your router uses it How to proceed Connect the intertechno...

Page 7: ...find the serial number S N on the label on the bottom of your intertechno MasterGate Distinctions are made between S N 850 orV1 0 or S N 910 or higher or V2 0 or higher the following description appl...

Page 8: ...tiple users to use the configuration you created Reset Your intertechno MasterGate is reset to factory settings Step 3 Create default configuration configuration menu 6 The default configuration is di...

Page 9: ...ch were built in 1995 or after You can give any receiver any name and even choose from different icons Ensure that the name of the receiver does not contain any special characters or numbers as they a...

Page 10: ...lected from your smartphone gallery ATTENTION The icon will only be displayed on the respective local smartphone Remove photo The icon is removed and the previously selected icon is displayed Pairing...

Page 11: ...s the pairing button on your receiver and Pairing in the app Then test your smart home devices by clicking on ON or OFF Was the pairing successful Then touch the green box 15 If you have a receiver wi...

Page 12: ...ct or move cabinets e g ifyou want to modify connections Use transmitters sensors to trigger defined dimming values for receivers Have the option to create custom automatic power shut offs for receive...

Page 13: ...sensors wallswitches and infrared devices which you have previously set up 18 A progress display in percent will show how many receivers sensors are already paired 19 Click on the respective transmit...

Page 14: ...ial characters and numbers are not permitted as they create difficulties for voice command Defining basic moods 22 Select the receiver to be used for the basic mood Only previously selectedreceivers w...

Page 15: ...tion to match the duration of the scenario the transmitter sensor will behave according to the default configuration 24 Click on the transmitter sensor for which you want to match the property to the...

Page 16: ...background for this automation rule to be used The app must always have permission to perform its GPS queries Twilight A scenario can be activated at sunrise or sunset Time Day A scenario can be trig...

Page 17: ...turn red which means that the intertechno MasterGate app is waiting for a voice command Make sure the system volume is activated as the intertechno MasterGate app won t be able to speak back to you ot...

Page 18: ...to copy and paste into the Verification link field Make sure that you only copy the verification link and not the text above it 4 Click on Link Your Amazon account is now linked to your intertechno M...

Page 19: ...they would like to receive notifications for The PUSH notification will appear 1 3 minutes after the sensor has been triggered The intertechno MasterGate app must be active in the background for this...

Page 20: ...ntertechno MasterGate displayed in blue will inform you that the operation was completed successfully Your custom configuration will not be erased by a firmware update Step 11 Update summertime winter...

Page 21: ...30 60 seconds until the intertechno MasterGate is ready for operation otherwise Default configuration not transferred or update of default configuration not possible If applicable go to configuration...

Page 22: ...number of receivers that can be switched off using an automatic power shut off 10 Maximum number of receivers which can be switched on off by a scenario 20 Maximum number of delay modules in scenarios...

Reviews: