manualshive.com logo in svg
background image

OPERATION

Model SL-5330

Motion Sensor
Light Control with
Protective Lamp
Shields

© 2003 DESA Specialty Products™

598-1131-01

* resets to Auto Mode at dawn.

TEST

Light Control

Sensor

Cover

Plate

Lamp Holders

6 Screws

(3 sizes included)

Gasket

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.

This package includes:

Requirements

• The Light Control requires 120-volts AC.
• If you want to use the Manual Mode, the control must

be wired through a switch.

• Some codes require installation by a qualified

electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

TEST 1  5  20

ON-TIME

Put ON-TIME switch on the sensor
bottom to TEST.

MANUAL MODE

ON-TIME

TEST  1  5  20

... back on.

AUTO

1 Second OFF

then...

Put the ON-TIME switch in the 1, 5
or 20 minute position.

Note: When first turned on wait about 1 

1

/

2

 minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

Mounting Bolt

Mounting Strap

Rubber Plug

Plastic Hanger

2 PAR Lamps

2 Wire

Connectors

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Auto

1, 5, 20 min.

x

Manual

Until Dawn*

x

Move ON-TIME Switch to

1, 5 or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.

Содержание SL-5330

Страница 1: ...TIME switch on the sensor bottom to TEST MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 20 minute position Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate Manual mode only works at night because daylight returns the sensor to AUTO Flipthelightswitchoffforonesecond thenbackontotogglebetweenAUTO and MANUAL MODE Ma...

Страница 2: ...actory setting When screwing in the floodlamps do not overtighten For eave mount only Swing the sensor head towards the clamp screw joint Ifthesensorpopsoutoftheballjoint loosentheclamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Thenrotatethesensorheadclockwise180 sothe controls face down Wall Mount Eave Mount For under eave installation the sensor head mu...

Страница 3: ...r head up down or sideways to change the cov eragearea Keepthesensor at least 1 2 5 cm away from the lamps Adjust the RANGE as needed RANGEsettoohigh may increase false triggering Secure the sensor head s aim by tightening the clamp screw Do not over tighten the screw Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 20 minutes Clamp Screw Ball Joint Aim Sensor ...

Страница 4: ...UCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDEN TAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR ...

Отзывы: