![International comfort products F9MVE Installation Instructions Manual Download Page 38](http://html1.mh-extra.com/html/international-comfort-products/f9mve/f9mve_installation-instructions-manual_2079721038.webp)
INSTALLATION INSTRUCTIONS
Gas Furnace: (F/G)9MVE
38
440 01 4400 03
Specifications subject to change without notice.
Table 13
Approved Combustion-Air and Vent Pipe, Fitting and Cement Materials (U.S.A. Installation)
ASTM
SPECIFICATION
(MARKED ON
MATERIAL)
MATERIAL
PIPE
FITTINGS
SOLVENT CEMENT AND
PRIMERS
DESCRIPTION
D1527
ABS
Pipe
−
−
Schedule
−
40
D1785
PVC
Pipe
−
−
Schedule
−
40
D2235
For ABS
−
−
Solvent Cement
For ABS
D2241
PVC
Pipe
−
−
SDR
−
21 & SDR
−
26
D2466
PVC
−
Fittings
−
Schedule
−
40
D2468
ABS
−
Fittings
−
Schedule
−
40
D2564
For PVC
−
−
Solvent Cement
For PVC
D2661
ABS
Pipe
Fittings
−
DWV at Schedule
−
40 IPS sizes
D2665
PVC
Pipe
Fittings
−
DWV
F438
CPVC
−
Fittings
−
Schedule
−
40
F441
CPVC
Pipe
−
−
Schedule
−
40
F442
CPVC
Pipe
−
−
SDR
F493
For CPVC
−
−
Solvent Cement
For CPVC
F628
ABS
Pipe
−
−
Cellular Core DWV at Schedule
−
40 IPS
sizes
F656
For PVC
−
−
Primer
For PVC
F891
PVC
Pipe
−
−
Cellular Core Schedule
−
40 & DWV
Figure 41
Vent Coupling and Adapter with
Gaskets
Attach gaskets to vent pipe and combustion air adapters
A13074
Vent Coupling and Adapter
Figure 42
Vent Pipe Flush with Adaptor
VENT PIPE ADAPTER WITH GASKET INSTALLED ON FURNACE.
VENT PIPE IS CUT FLUSH WITH TOP OF ADAPTER. PRIME AND
CEMENT VENT PIPE TO ADAPTER. ALLOW TO DRY BEFORE IN-
STALLING VENT COUPLING.
A13076A
Figure 43
Vent Pipe Flush Showing Coupling
ALIGN NOTCHES IN VENT PIPE COUPLING OVER STAND
−
OFF ON ADAPTER. TORQUE LOWER CLAMP 15 LB
−
IN. WHEN
REMAINING VENT PIPE IS INSTALLED, TORQUE UPPER
CL AMP TO 15 LB
−
IN.
A13076B