Replacement filters should be of the same type and size as the origi-

nal filters, to ensure adequate air flow and filtering. A disposable low

velocity filter can be replaced with a washable high velocity type. Do

not replace a high velocity filter with a disposable low velocity filter,

except as permitted below.

If a cleanable (high--velocity) filter(s) is to be replaced with a dispos-

able (low--velocity) filter(s), the airflow area of the filter(s) must be

doubled (i.e., a second filter of the same size must be installed so

that only half of the air goes through each filter). A second return--air

duct to the furnace may be required in which to install the second

filter. Modification of a furnace installation shall comply with the lo-

cal installation code and the furnace installation instructions, and

shall be made only by a Qualified Service Agency.

NOTE: Some filters are marked with an arrow to indicate the

proper direction of air flow through the filter. The air flow direc-

tion will be towards the blower motor. Make sure filter is

installed correctly.

Filter Replacement -- Upflow

The filter may be installed inside the bottom of the furnace blower

compartment, or the filter(s) rack may be installed under the furnace

or on either or both sides of the furnace. A plastic end cap(s) is in-

serted in the filter rack(s) after the filter(s) is installed. The end cap

keeps air from escaping around the open end of the filter rack. See

Figure 7

and

Figure 8

for side and bottom locations. Rack end cap

is similar for bottom mounted filter rack.

Filter rack(s) attached to the outside of the furnace is made so the

filter simply slides out one end for removal.

RISK OF REDUCED FURNACE LIFE
Use of excessively dirty and/or restrictive air

filters

may

increase

furnace

operating

temperatures and shorten the life of the furnace.

Filters specified for the furnace are rated at a

maximum of 600 FPM air velocity and sized for the

furnace’s airflow rate. Replacement filters must be of

equivalent type, size, and rating except as described

below.
Disposable, low--velocity filters may be used to replace

washable, high--velocity filters, providing they are sized

for 300 FPM or less.
If you are uncertain of the type of replacement filter to use,

consult the furnace installer or a qualified service agency

for assistance.

!

CAUTION

Filter Replacement -- Bottom or Side

Mounted Filter Rack Outside Furnace

1. Turn

OFF

electric power to furnace.

2. Remove the end cap from the filter rack.
3. Slide the filter out of the filter rack. See

Figure 7

.

4. Inspect the filter(s) and replace or clean washable types. If

filter is aluminum mesh it should be recoated with filter coat-

ing spray.

5. Reinstall the end cap in the filter rack.
6. Turn on electric power to furnace.

Filter Rack Outside Furnace

Figure 7

25--24--62--1

Filter Rack End cap

Filter Replacement -- Bottom Mounted Filter

Inside Furnace,

1. Turn off electric power to furnace.
2. Remove blower door.
3. Slide filter straight out toward you. See

Figure 8

.

4. Inspect the filter(s) and replace or clean washable types. If

filter is aluminum mesh it should be recoated with filter coat-

ing spray.

5. Replace blower door.
6. Turn on electric power to furnace.

Figure 8

Bottom Mounted Filter

Inside Furnace

25--24--18--1

9

²

Center Clip
side--to--side

Filter Replacement -- Horizontal and

Downflow *8MPN/L (Not *8DNL)

The filter may be installed at the inlet end of the blower compart-

ment, either inside or outside the furnace. Side inlet filter locations

are not permitted for horizontal or downflow applications.

Filter Replacement ---- Downflow *8DNL

Two filters are supplied with all *8DNL downflow models. (See to

Figure 9

) Refer to note for proper size. The filters are installed

through the top of the downflow furnace from the right side. To re-

move filter, refer to

Figure 9

for the following steps.

NOTE:

Two (2) 16

²

x 18

²

cleanable high--velocity filters are recom-

mended. A *8DNL downflow furnace with airflow up to 1200 cfm is

permitted to replace the 16

²

x 18

²

cleanable high--velocity filters

with two 16

²

x 18

²

disposable filters.

Summary of Contents for *8MPN/L

Page 1: ...hbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or...

Page 2: ...nal injury or product or property damage NOTE is used to highlight suggestions which will result in en hanced installation reliability or operation Signal Words in Manuals The signal word WARNING is u...

Page 3: ...d safe operation of the furnace for com bustion and ventilation of flue gases See the Combustion Air Your Safety section of this manual 5 Familiarize yourself with the possible air starvation sig nals...

Page 4: ...for ventilation and or combustion WARNING New materials and methods are being used in construction and re modeling which resultin lowerenergy costs forheating and cooling It may also mean your applia...

Page 5: ...ow for a few minutes to bring in cool drier air 3 Cook with pans covered 4 Take shorter baths or showers with cooler water 5 Install a fresh airintake duct Cold dry air broughtin fromout side to the f...

Page 6: ...e Panel on Some Models Diagnostic Light Ignitor Flame Sensor not shown 25 24 78 1 Pressure Switch Some models have one Component Locations for 80 Furnaces 4 Position Figure 4 25 24 79 1 Heat Exchanger...

Page 7: ...if equipped with a System Select Switch 2 Turn OFF all electric power to the furnace at the disconnect switch or circuit breaker 3 Remove the burner compartment door by removing the two 2 screws secur...

Page 8: ...3 1 Disconnectthe 1 2 I D rubberhose fromthe vent drain fitting ortee thatis locateddownstreamofthe combustionblower Insert a funnel into the hose and pour four 4 ounces of sani tary type RV antifree...

Page 9: ...sized for the furnace s airflow rate Replacement filters must be of equivalent type size and rating except as described below Disposable low velocity filters may be used to replace washable high velo...

Page 10: ...u See Figure 8 4 Inspect the filter s and replace or clean washable types If filter is aluminum mesh it should be recoated with filter coating spray 5 Replace blower door 6 Turn on electric power to f...

Page 11: ...nal components such as exterior panels refractory combustion chambers oil nozzles refrigerant refrigerant inspection and refrigerant reclaiming freight and or handling charges associated with any repa...

Page 12: ...or 20 years from the date of original installation ADDITIONAL TERMS FOR OIL FURNACE APPLICATIONS ONLY 1 OIL BURNERS A replacement for 5 years from date of original installation for Oil Burner Parts 2...

Reviews: