5. Symbologies
Code 93
82
ScanPlus S Series - Installation Manual
Code 93
- alphanumeric full ASCII symbology - letter case defined
not active (*)
\41\5F\60
active
\41\5E\60
barcode length
= <barcode data>
- minimum length possible = 1 character
- use the "compose minimum length" option if you know the minimum length of the codes in your
application !!!
any length (*)
\45\42\00\60
- cancels the last minimum length selection and
accepts any valid length (1 or more characters)
compose minimum length: [range: 1-50]
\45\42\60
- enter a number string and scan End Selection
(Appendix C)
- to optimize decoding performance and increase
security, select the same length as the minimum
length in your application (do not select a shorter
length !!)
Summary of Contents for ScanPlus S Series
Page 1: ...P N 0 360049 02 ScanPlusSSeries Installation Manual ...
Page 8: ...Contents 8 ScanPlus S Series Installation Manual ...
Page 14: ...2 Reset all parameters 14 ScanPlus S Series Installation Manual ...
Page 68: ...4 Data transmission settings OCIA cash registers 68 ScanPlus S Series Installation Manual ...
Page 83: ...5 Symbologies Code 93 ScanPlus S Series Installation Manual 83 minimum length 6 45 42 06 60 ...
Page 120: ...6 Operating settings beeps green indicator LED 120 ScanPlus S Series Installation Manual ...
Page 150: ...C Number codes 150 ScanPlus S Series Installation Manual 8 18 60 9 19 60 end selection 64 60 ...
Page 156: ...Index 156 ScanPlus S Series Installation Manual ...