5. Symbologies
MSI Code
ScanPlus S Series - Installation Manual
93
barcode length
= <barcode data> + <check digit>
- minimum length possible = 2 characters
- use the "compose minimum length" option if you know the minimum length of the codes in your
application !!!
any length
\44\5F\00\60
- cancels the last minimum length selection and
accepts any valid length (2 or more characters)
compose minimum length: [range: 2-50]
\44\5F\60
- enter a number string and scan End Selection
(Appendix C)
- to optimize decoding performance and increase
security, select the same length as the minimum
length in your application (do not select a shorter
length !!)
minimum length = 6 (*)
\44\5F\06\60