Section 7:
Checking Out and Troubleshooting
the System
After you have completed installation and programming, make sure the system is working OK by
completing the procedures listed below. Later on, if problems develop in using the system, going
over these same procedures will help you troubleshoot the problem.
Check time of day setting
What to do
If it doesn’t work
Reference/Procedure
Verify that the display on the
Pump Timer is showing the
correct time of day.
Verify that power is ON to
the panel.
Turn the main circuit breaker that feeds the panel to the
ON position.
Use a voltmeter to verify that voltage is present at the
buss terminals. See page
12
.
1.
2.
Verify that the breaker is
turned on and 120VAC is
wired to the upper chassis
and Pump Timer.
Use a voltmeter to verify that voltage is present at the
breaker and Pump Timer Power terminals. See pages
14
.
Verify the condition of the
Pump Timer battery.
Remove the clock and verify the battery in the rear of the
clock is good. See page
22
.
Follow instructions for
setting the correct time.
See page
21
for setting time.
Replace Pump Timer if
unsuccessful.
See page
8
for ordering a new Timer Clock.