7
Source Voltage Selector Jumper
This jumper needs to be set to the
proper input voltage for the clock
circuitry. The factory default position
for this jumper is the 240 Volt position.
WARNING
If voltage selector is in wrong position,
the
F1
fuse
will
blow and
you
may
cause damage to circuit board voiding
the manufactures warranty.
CUT WIRES HERE AND USE WIRE NUTS FOR
CONNECTING FIREMEN SWITCH WIRES FROM
HEATER.
If the input voltage for the clock is 120
Volts, this jumper needs to be set to
the 120 Volt position.
120 240V
120 240V
Figure #1
120/240V
Fuse
34
Cleaner Pump Display
The cleaner pump
should always be connected to
circuit #3
and the mode setting should be set to #3 or
#4, depending on the filter pump configuration. Before
the cleaner pump can come on, circuit #1 (filter pump)
must be on for more than 30 seconds. If the filter pump
is off and the cleaner pump must turn on because of a
manual action or the beginning of a program, the control
first forces the filter pump to go on, then 30 seconds
later, turns the cleaner pump on. A
blinking cleaner
pump icon
indicates the cleaner pump will start after the
minimum 30-second delay.
Like the other outputs, the cleaner pump icon is solid
after the cleaner pump has turned on. In the event
someone manually turns off the filter pump, the cleaner
pump will also turn off.
If the control is connected to a two-speed pump, with a
cleaner pump connected to circuit #3, the control should
be in Mode 4. If the filter pump is off, or in low speed,
and the cleaner pump must turn on because of a manual
action or the beginning of a program, the control first
forces the filter pump to turn on high speed, then 30
seconds later, turns the cleaner pump on.