POOL / SPA EQUIPMENT CONTROL ACCESSORIES
WARNING
Risk of Fire or Electrical Shock!
Turn power OFF at main panel before installing the Digital Clock Mechanism
and/or this Safety Shield.
SAFETY SHIELD KIT
A) If this is what you have...
(Two Mechanical timers in one Panel)
B) ...and want to convert to this...
(Install a Digital Clock Mechanism)
C)...you also have to do this.
(Install the Safety Shield, supplied.)
A 1. Disconnect electricity at the Main Panel.
A 2. Optional - label each lead or make a
diagram of Leads connected to terminals
of each timer.
A 3. Remove Time Clocks.
B 1. Review the Installation Manual of the
Digital Mechanism you are about to
install.
B 2. Make Low voltage accessory
connections, if any, on back of
Mechanism and snap Mechanism into
one of the brackets.
B 3. Make high voltage connections to the
Digital Mechanism terminals.
B 4. If applicable, follow instructions in
Manual for installing Low Voltage
accessories.
For added safety, you also have to install the
Safety Shield included with the Digital Clock
Mechanism.
C 1. Using the two #10 self tapping screws,
attach Shield to the Dead Front as
shown.
158--01326
Safety Shield
Mounting Screws
Deadfront of Panel