20
Mode 2
– (Pump High, Pump Low, Aux3) Circuit one
and two are dedicated single pole outputs for a two-
speed pump load. Circuits one and two will never be
ON at the same time, consistent with a two-speed pump
application. Circuit three is single pole circuit for a
generic load, and independent of circuits one and two.
120V or
240V source
120V or 240V
Two Speed Pump
Common
120V or
240V source
120V or
240V load
Low
Speed
Line
High
Speed
Line
21
Mode 3
– (Pump, Aux2, Cleaner Pump) Circuit one
and three are dedicated single pole outputs for a single
speed pump working with a pressure side cleaner
pump. Circuit three will never come on unless circuit
one is on for at least one minute, consistent with a
pressure side cleaner pump. Circuit two is a single
pole circuit for a generic load, independent of circuits
one and three.
120V or
240V source
120V or
240V load
120V or
240V source
120V or
240V Cleaner
Pump Load
120V or
240V Pump
Load
120V or
240V source