background image

4 / 4 

P/N 1073110-EN 

• REV 

• ISS 

02FEB17 

 

Power a 24 VAC camera: 

Heater

 

Fan

 

 

24 

VAC camera power 

supply

 

24 

VAC input

 

3. 

When you have completed connecting the 

cables, power on the housing, adjust the lens 

to zoom and

 

focus.

  

Zoom

 

 

Focus

 

4. 

C

lose the cover of the housing and fasten the 

clamps

 

to

 

finish the installation

 

Specifications 

Dimensions (L × W × H)

 

445.3 ×

 

169.2 × 110 mm 

 

(17.5 × 6.7 × 4.3 in )

 

Weight

 

1900 

g

 

(4.2 lbs

.

)

 

Working temperature

 

-40 

to +60 

 

(

-40 

to +

140

 °F

 

)

 

Temperature control

  

Heater on: 5

 

 

±5

 

, fan operating 

for constant temperature;

 

Fan on: 40

 °C 

±5

 

, for heat 

dissipation

 

Power supply

 

24 

V

AC 4 A

. Purchased separately.

 

Power consumption

 

40 

W

 

max.

 

Environmental rating

 

IP66

 

Legal and regulatory 

information  

 

Trademarks and 

patents

 

The

 

trade names used in this document may 

be trademarks or registered trademarks of the 

manufacturers or vendors of the respective 

products.

 

Certification

 

 

 

 

 

Copyright

 

© 2017 

United Technologies Corporation. All 

rights reserved.

 

Interlogix is part of UTC 

Climate, Controls & Security, a unit of United 

Technologies Corporation.

 

Contact information 

For contact information, see www.interlogix.com or 

www.utcfssecurityproducts.eu.

 

Summary of Contents for TruVision TVC-M2-WM

Page 1: ...0 EN REV C ISS 02FEB17 1 4 TruVision Box Camera Outdoor Housing with Heater TVC OH2 H and Wall Mount TVC M2 WM Installation Instructions Dimensions Housing Internal Space Accessories Camera base plate dimensions ...

Page 2: ...VC 3201 TVC 1202 TVC 3202 TVC 5401 TVC 5402 TVC 5403 Installation The housing is shipped with a TVC M2 WM box camera wall mount To attach a box camera to the box camera outdoor housing TVC OH2 H Note Prior to installing the TVC OH2 H housing run the interconnect cables and mount the wall bracket TVC M2 WM Refer to the TVC M2 WM Wall Mount Installation Instructions 1 Loosen the two latches located ...

Page 3: ... OFF during installation 6 Connect the power supply purchased separately cable to the 24 VAC input terminals on the terminal panel Terminals 24 VAC output Connect the camera 24 VAC input 12 VDC Connect the camera 12 VDC power input The positive negative terminals should be distinguished RS 485 Port Reserved for wiper control the wiper feature is not supported in this model Note 24 VAC 4 A UL liste...

Page 4: ... Heater on 5 5 fan operating for constant temperature Fan on 40 C 5 for heat dissipation Power supply 24 VAC 4 A Purchased separately Power consumption 40 W max Environmental rating IP66 Legal and regulatory information Trademarks and patents The trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Certification Cop...

Reviews: