background image

13

 

1.

Open panel cover. Panel announces, Use numbered 
keys to enter ID. 

2.

Enter Access Code using the numbered keys. Panel 
announces, Please select from Start Menu.

3.

Press Delete from the Start menu. Panel announces, 
Select from main menu

4.

Press Option #. Panel announces, Option 1, press 
again for next option or done to select.

5.

Press 43. Panel announces, Option 43, press again for 
next option or done to delete.

6.

Press DONE. Panel announces, Option 43 deleted.

The panel will call the pager to indicate the 
following:

No activity - A no activity alarm is called in if the 
programmed amount of time passes, and no activity 
has occured on your system. Examples of such are: 
the panel is not subdisarmed, disarmed, sensors 
armed, a key has not been pressed or a sensor has not 
been tripped. Tripping of non-intrusion chime sensors 
is not considered activity. The no activity time period 
is programmed by your installer.

Latchkey - A latchkey report is called when the sys-
tem is not disarmed by a predetermined time. The 
latchkey time is programmed by the user (Option 03). 
Latchkey must be enabled when arming.

Phone Test - A phone test report is called in when a 
phone test has been performed. 

Disarming -  A disarming report is called in when the 
system is disarmed. This option is programmed by 
your installer.

Arming - An arming report is called in when the sys-
tem is armed. This option is programmed by your 
installer. 

Fail to Disarm - A fail to disarm report is called in 
when the system is not disarmed by the time pro-
grammed by the installer.

Fail to Arm - A fail to arm report is called in when 
the system is not armed by the time programmed by 
the installer.

AC Power Failures - An AC power failure is called 
in after loss of power. To avoid false alarms, your 
installer has programmed the panel to wait at least a 
few minutes (or up to several hours) before calling in.

AC Power Restore - A restore will be reported when 
power is restored.

Alarms - Alarm reports include: Emergency, Intru-
sion, and Fire.

Option 55: Status Sounds

Add allows you to set the volume for status sounds, such 
as arming beeps, trouble beeps, and status beeps. The low-
est volume setting is 1, the highest is 10.

1.

Open panel cover. Panel announces, Use numbered 
keys to enter ID. 

2.

Enter Access Code using the numbered keys. Panel 
announces, Please select from Start Menu.

3.

Press Add from the Start menu. Panel announces, 
Select from main menu

4.

Press Option #. Panel announces, Option 1, press 
again for next option or done to select.

5.

Press 55. Panel announces, Option 55, press again for 
next option or done to select

6.

Use the numbered keys to enter the desired volume 
setting (01-10).

7.

Press DONE.

Delete sets the volume of status sounds to the default set-
ting (7).

1.

Open panel cover. Panel announces, Use numbered 
keys to enter ID. 

2.

Enter Access Code using the numbered keys. Panel 
announces, Please select from Start Menu.

3.

Press Delete from the Start menu. Panel announces, 
Select from main menu

4.

Press Option #. Panel announces, Option 1, press 
again for next option or done to select.

5.

Press 55.

6.

Press DONE.

Trouble Beeps

Your security system is able to automatically test itself for: 

Power failures

Low batteries

Non-working sensors

Communication troubles with the Central Monitoring 
Station

When your security system detects one of the problems 
above, six rapid beeps sound every minute, until the trou-
ble condition is corrected.

AC Power Failure

This condition occurs if your security system has been 
accidentally unplugged or if there has been an AC power 
outage. The backup battery will take over. If AC power is 
not restored within 15 seconds, the panel will go dark and 
alert you with trouble beeps. If you press any button, the 
display will light and pressing SYSTEM STATUS will 
confirm the AC power failure. If AC power is not restored 
within a programmed period of time (5-254 minutes) the 
system will call the central monitoring station (if pro-
grammed by installer). The backup battery, if fully 
charged, will last for 18 - 24 hours with no AC power.

Silencing Trouble Beeps

To stop the trouble beeps, press the SYSTEM STATUS 
button or arm/disarm the system while the trouble condi-
tion exists. Trouble beeps will begin 4 hours later, unless 
the trouble condition is corrected.

Summary of Contents for Simon 3

Page 1: ...trol Panel 6 Phone Commands 7 How to Use Your Touchpads 7 Remote Handheld Touchpad 7 Keychain Touchpad 7 Programming Your System 8 Programming Instructions 8 Access Codes 9 Light Control 9 Programming Options 10 Option 01 Panel Beeps 10 Option 02 Panel Voice 10 Option 03 Latchkey Time 11 Option 36 and 37 Sensor Activated Light Lockout Start and Stop Times 11 Option 41 Voice Chime 12 Option 42 Spea...

Page 2: ... affected equipment and the panel receiver to separate outlets on different branch circuits Consult the dealer or an experienced radio TV technician for help FCC Part 68 This equipment complies with Part 68 of the FCC Rules Located on this equipment is a label that contains among other information the FCC registration number and the ringer equivalence number REN for this equipment If requested thi...

Page 3: ...rity system primarily from within the home Keychain Touchpads are used to control the security sys tem from within or near the outside of your home Sensors Indoor Motion Sensors detect motion in a protected indoor area When motion is detected the panel may respond by sounding chimes or an alarm Outdoor Motion Sensors detect motion in a protected outdoor area When motion is detected the system may ...

Page 4: ... this manual to determine the mean ing of panel system beeps Your Exit Delay is set for ___ seconds Entry Delay Entry Delay is the amount of time the system gives you to disarm the system after entering the home This is pro grammed by the installer When you enter your home you will hear beeps during the entry delay see the table Sta tus Beeps of this manual to determine the meaning of panel system...

Page 5: ...med and the Disarm light will be lit WARNING If you enter your home and you hear alarm sirens or if controlled lights that should be off are on an intruder may be inside or another emergency may have occurred Leave immediately and call for help Subdisarm Your System 1 Enter your Master Access Code while the system is disarmed Panel announces System disarmed Disarm button light blinks and the syste...

Page 6: ... Lights Turn on designated lights with Lamp Modules at a spe cific time You can program what time the lights go on and off see Programming Light Control Turn Time Activated Lights on 1 Press Time Lights button Panel will announce time activated light on Time Lights button will be lit Turn Time Activated Lights off 1 Press Time Lights button Panel will announce time activated light off Time Lights ...

Page 7: ...n sounds used by the security system Temporal 3 refers to a contin uous pattern of 3 siren pulses then off for 2 seconds 3 siren pulses then off for 2 second Panel Indicator Lights Use the following table to understand the panel indicator lights Status Beeps Activity Beep Response ARM Doors Windows Exit delay and Entry delay beeps sound 2 times every 5 seconds and 2 times per second during the las...

Page 8: ...ur motion detectors Check the location of your smoke detectors Smoke detectors near bathrooms and kitchens can be tripped by steam and smoke from cooking Take note of system beeps voice announcements and indicator lights which indicate the current system sta tus How to Use an Off Site Phone You may use an off site phone to arm disarm your panel turn lights on and off check system status or conduct...

Page 9: ...dical emergency Keychain Touchpad If your installer programmed the Key chain Touchpad with no entry delay and you armed the system with the Keychain Touchpad you must disarm your system before entering the home to avoid caus ing an alarm If your installer programmed your system for Remote Touchpad Arming you must enter your home to start the entry delay before you can use your Keychain Touchpad to...

Page 10: ... Test follow the voice prompting To select a test press start over press prompting by a qualified technician Delete START MENU Add Version 3 MAIN MENU Remote Sensor Control Light Option Sensors Entry Exit Delay CONTROL MENU Press for program information Instruction Add Option Summary Unit Add Press Clock Set Press Set Clock DONE Chime Voice Latchkey Time Panel Voice Add Option Press Option 42 Opti...

Page 11: ...el voice prompts you to Please select from START MENU Press the Add button on the START MENU 4 The panel voice prompts you to Select from MAIN MENU Press the Access Code button on the MAIN MENU 5 The panel voice responds with Master Code press again for next access code or DONE to select or CANCEL to quit Press the access code button again to hear the next access code When you hear the access code...

Page 12: ...ss Option Panel announces Option 1 press again for next option or done to select 5 Press DONE Panel announces Option 1 is on Delete turns off panel piezo beeps 1 Open panel cover Panel announces Use numbered keys to enter ID 2 Enter Access Code using the numbered keys Panel announces Please select from Start Menu 3 Press Delete from the Start menu Panel announces Select from main menu 4 Press Opti...

Page 13: ...ou don t want sensor activated lights to be active during daylight hours set the lockout start time to begin at dawn and set the stop time option 37 to coin cide with sunset Option 36 Sensor Activated Light Lockout Start Time Add enables sensor activated light lockout start time mid night to 11 59 P M 1 Open panel cover Panel announces Use numbered keys to enter ID 2 Enter Access Code using the nu...

Page 14: ...nter Access Code using the numbered keys Panel announces Please select from Start Menu 3 Press Add from the Start menu Panel announces Select from main menu 4 Press Option Panel announces Option 1 press again for next option or done to select 5 Press 42 Panel announces Option 42 press again for next option or use numbered keys to enter option 6 Enter the voice level 1 8 with the numbered keys 7 Pa...

Page 15: ...ows you to set the volume for status sounds such as arming beeps trouble beeps and status beeps The low est volume setting is 1 the highest is 10 1 Open panel cover Panel announces Use numbered keys to enter ID 2 Enter Access Code using the numbered keys Panel announces Please select from Start Menu 3 Press Add from the Start menu Panel announces Select from main menu 4 Press Option Panel announce...

Page 16: ...or Tampered This condition occurs when a sensor is physically tam pered with If the system is armed an alarm will occur For example the cover is taken off of one of the sensors Your system will indicate this condition to you by causing the System Status button to light When you press this button the system responds with Sensor Name tampered Cor rect the problem by resetting the sensor If this cond...

Page 17: ...ronmental prob lems All alarm systems are subject to possible compromise or failure to warn for a variety of reasons If sirens are not placed within hearing range of per sons sleeping in remote parts of the premises or if they are placed behind doors or other obstacles If intruders gain access through unprotected points of entry or areas where sensors have been bypassed If intruders have the techn...

Page 18: ...ne should enter the premises if they hear sirens in the house If you arrive at the premises and hear sirens do not enter Call for emergency assistance from a neighbor s phone Your Floor Plan Use the following guidelines when drawing your floor plan use the next page to draw your floor plan Show all building levels Show exits from each room two exits per room are recommended Show the location of al...

Page 19: ...17 ...

Page 20: ...ccess Code while system is disarmed Disarm ARM Motion Sensors Press once ARM Doors Windows Press once ARM Doors Windows Press each button once ARM Doors Windows Press twice Press once Press once Press twice Press once if programmed Access Code Press twice Press twice Press Master Code 3 3 Press both Emergency buttons and hold for 3 seconds Press twice Press 3 times Press both hold for 3 seconds Qu...

Reviews: