Chapter 6: Command line mode
396
NS3550-8T-2S Industrial Managed Switch User Manual
transmitted as fast as possible - this gives protection reliability in the path end-
point.
Syntax:
MEP ais config [<inst>] [<prio>] [1s|1m] [set|clear] [enable|disable]
Parameters:
<inst>
: Instance number
<prio>
: OAM PDU priority
1s|1m
: Transmit period for AIS
1s - to send OAM Frames in the rate of 1 per second
1m - to send OAM frames in the rate of 1 per minute
set|clear
: Protection usability set/clear
enable|disable
: enable/disable
MEP LCK Configuration
Description:
MEP LCK configuration
'prio' is the priority (PCP) of transmitted AIS frame
'1s|1m' is the number of AIS frame pr. second.
Syntax:
MEP lck config [<inst>] [<prio>] [1s|1m] [enable|disable]
Parameters:
<inst>
: Instance number
<prio>
: OAM PDU priority
1s|1m
: Transmit period for LCK
1s - to send OAM Frames in the rate of 1 per second
1m - to send OAM frames in the rate of 1 per minute
enable|disable
: enable/disable
MEP Link Trace Configuration
Description:
MEP Link Trace configuration
'prio' is the priority (PCP) of transmitted LTM frame
'mac_addr' is the unicast MAC of target MEP/MIP
'mep' is the peer MEP-ID of target MEP - only used if 'mac_addr is 'all zero'
'tll' is the TLL in the transmitted LTM.
Syntax:
MEP lt config [<inst>] [<prio>] [<mac_addr>] [<mep>] [<ttl>] [enable|disable]
Parameters:
<inst>
: Instance number
<prio>
: OAM PDU priority
<mac_addr>
: MAC address ('xx-xx-xx-xx-xx-xx' or 'xx.xx.xx.xx.xx.xx' or
'xxxxxxxxxxxx', x is a hexadecimal digit)
<mep>
: This MEP id (0-0x1FFF)
<ttl>
: LT - Time To Live
enable|disable
: enable/disable