immediately takes the port out of the Guest VLAN and starts authenticating the supplicant according to the port mode.
If an EAPOL frame is received, the port will never be able to go back into the Guest VLAN if the "Allow Guest VLAN if
EAPOL Seen" is disabled.
The 802.1X Guest VLAN setting screens in
Figure 4-9-7
&
Figure 4-9-8
appear.
Figure 4-9-7
Guest VLAN Setting Page Screenshot
The page includes the following fields:
Object
Description
Guest VLAN ID
This is the value that a port's Port VLAN ID is set to if a port is moved into the
Guest VLAN. It is only changeable if the Guest VLAN option is globally
enabled.
Valid values are in the range [1~4094].
Guest VLAN Enabled
A Guest VLAN is a special VLAN - typically with limited network access - on
which 802.1X-unaware clients are placed after a network administrator-defined
timeout. The switch follows a set of rules for entering and leaving the Guest
VLAN as listed below.
The "Guest VLAN Enabled" checkbox provides a quick way to globally
enable/disable Guest VLAN functionality.
When checked, the individual ports' ditto setting determines whether
the port can be moved into Guest VLAN.
When unchecked, the ability to move to the Guest VLAN is disabled for
all ports.
Summary of Contents for NS3500-28T-4S
Page 1: ...NS3500 28T 4S User Manual P N 1072835 REV 00 01 ISS 14JUL14 ...
Page 41: ...41 3 Press the Apply button to save running configuration to startup configuration ...
Page 166: ...166 Figure 4 7 4 Multicast Flooding ...
Page 260: ...260 Buttons Click to clear the statistics Click to refresh the statistics ...
Page 282: ...282 Figure 4 9 66 Global DoS Setting Page Screenshot ...
Page 296: ...296 ...
Page 303: ...303 ...