Chapter 2: Installation
26
FlexZone™ Product Guide
Figure 22: Cable at fence posts
At corners or heavy gauge posts
Install sensitivity loops at all fence corners and at any heavy gauge fence posts.
Figure 23: Sensitivity loops at corner and at heavy gauge posts
At software defined zone boundaries
Optionally, install zone demarcation loops at soft zone boundaries for increased
zone isolation. The extra cable helps ensure that valid targets are located
accurately in the correct zone. See Figure 23 above for zone demarcation loop
layout recommendations and Figure 24 below for suggested use.
secure the cable at both sides
sensor cable
fence post
the cable should be snug
against the fence post
(not stretched tightly)
of each fence post
sensor cable
chain-link fence
1 m
(3.3 ft.)
0.5 m
(20 in.)
0.5 m
(20 in.)