Glossary
FlexZone™ Product Guide
95
UCM configuration
To use UltraLink modular I/O system outputs to report FlexZone alarm and
supervision conditions establish a UCM connection to the FlexZone processor.
Note:
Refer to the UltraLink Modular I/O system instruction sheet and the UCM
help file for additional details on NM Mode operation.
Select the Remote Cfig tab and specify the outputs that will activate to
annunciate the required alarm and supervision conditions (see Figure 77 on page
94).
Note:
Output assignments for Comm Fail and device mismatch for each
connected device are made via a UCM connection to the UltraLink processor.
Select the Side A Cfig or Side B Cfig tabs to assign outputs to Cable segments
for reporting Zone alarms (see Figure 79 on page 96).
Figure 78: Setting up the Remote Configuration outputs
Select the Remote Cfig tab
Select the arrow and use the drop-down menu to
specify the appropriate output