![Intergraph ImageStation ZII and use Installation And Use Manual Download Page 16](http://html1.mh-extra.com/html/intergraph/imagestation-zii-and-use/imagestation-zii-and-use_installation-and-use-manual_2076427016.webp)
12
To verify the two-handed controller buttons and X, Y data transmission:
1. Set
terminal to com1, 9600, N, 8, 1, raw as shown on the screen menu, using the following
keyboard commands:
Press
ALT
+
N
successively to select com1.
Press
ALT
+
B
successively to select the proper baud rate (9600).
2. Set
terminal to point mode by typing
SHIFT
+
P
and then pressing
ENTER
. The continuous data
stream stops.
3. Verify the cable connections to the Altek digitizer controller by typing
SHIFT
+
T
and then pressing
ENTER
. The following displays:
X axis size = 93 wires
Y axis size = 63 wires
If the wire count is not displayed, then verify all cable connections to the Altek digitizer
controller.
4. Display digitizer data transmission by typing
SHIFT
+
F
and
1
, and then pressing
ENTER
. Press any
button on the two-handed controller, and the X and Y location data begins to scroll. This
indicates the button is transmitting data. Test all of the buttons by pressing each one. The data
format is of the form
F +xxxxx +yyyyy
where
F identifies the button, and where x and y are numerical values.
5. Display data transmission in a continuous data stream by typing
SHIFT
+
S
and
2
, then pressing
ENTER
. The data displays continuously.
To verify the force stick functionality:
1. Set
terminal to com2, 9600, N, 8, 1, raw as shown on the screen menu using the following
keyboard commands:
Press
ALT
+
N
successively to select com2.
Press
ALT
+
B
successively to select the proper baud rate (9600).
2. Display version information by typing
SHIFT
+
V
and pressing
ENTER
. The following displays:
Intergraph Imaging Systems Stereo Cursor, Software version 1.2
PCBC080 ECO level 1
3. Activate the microprocessor to decode the force stick data by pressing
CTRL
+
Q
. Verify force stick
operation by moving the force sticks to watch the numbers change. This indicates the force sticks
are transmitting data. The data format is of the form
H:AA
X:
nnn
nnn
Y:
nnn
nnn
where
n is a numerical value.
The Altek digitizer controller provides you with significant capabilities for customization. It is
relatively easy to disable the Altek digitizer controller from the terminal program. Refer to the AC32
Digitizer Controller User’s Manual and Technical Reference for information on resetting memory to
the factory settings using the lowercase w1, w2, w3, w4 terminal commands.
CAUTION
If resetting the digitizer to the factory settings, be careful not to use the (uppercase) W1, W2, W3, or
W4 terminal commands.
Summary of Contents for ImageStation ZII and use
Page 1: ...ImageStation ZII Installation and Use February 1998 DHA023330...
Page 4: ......
Page 22: ...18...