Installation
3
and 3/3 which contain Port Bypass Circuits (PBC) that provide loop resiliency in the event of unplugged or failing
drives.
Notes
1
Figure 1–3
shows the logical routing of the FC-AL interface through the drive bays.
2
This figure does not represent the physical wiring of the enclosure.
1.5.2
FC-AL Physical Organization
Figure 1–4
shows the two FC-AL loops, these are each routed through independent LRC I/O cards fitted in the rear
of the enclosure. Either of these may be removed while the other is operating, thus providing fully redundant FC-
AL operation.
LRC Input/Output Modules are fitted in bays 3/2 and 3/3. Each module includes DB9 connectors for FC-AL
attachment, shown in
Figure 1–5
.
Figure 1–3
FC-AL Logical Layout
3/1
4/1
4/2
4/3
3/3
3/2
2/1
2/3
2/2
1/3
1/2
1/1
D
C
B
A
9
8
7
6
5
4
3
2
Drive Bays - Front View
Device ID (Low Order Bits)
Bay Number
Loop 1
Loop 2
Figure 1–4
Physical Organization
PBC
PBC
PBC
PBC
4/3
3/2
2/1
4/2
3/1
1/3
4/1
2/3
1/2
3/3
2/2
1/1
PBC
PBC
RPTR
RPTR
RPTR
RPTR
RPTR
RPTR
LRC/10
LRC/10
Backplane
Summary of Contents for Fibre Channel
Page 3: ...SS 1200 FCAL Rack Installation and User Guide Part No 19933 01 Issue 1 0 June 01 1998 ...
Page 22: ...SS 1200 FCAL User Guide 12 ...
Page 34: ...SS 1200 FCAL User Guide 24 ...
Page 48: ...SS 1200 FCAL User Guide 38 ...
Page 56: ...iv FCAL LRC I O Module ...
Page 66: ...FCAL LRC I O Module 8 ...
Page 69: ...SS 1200 FCAL Drive Carrier Module Installation Guide Part No 19935 01 Issue 1 0 June 01 1998 ...
Page 72: ...iv FC AL Drive Module ...
Page 82: ...FCAL Drive Module 8 ...