SS-1200-FCAL User Guide
10
1.4.4
Power Cord
(minimum requirements)
1.4.5
Environment
Power consumption (Normal
operation 12 x 9GB Drives)
800 VA
Power supply peak & operational
currents (per supply)
6.5 A Nominal @ 110V 10.5 A Peak @ 110V
Inrush Current
40/80 A @ 110/220VAC (25° cold start 1 PSU)
Cord Type
SV 0r SVT, 18 AWG minimum, 3 conductor
Plug
250V, 10A
Socket
IEC 320, 250V, 10A
Table A–1 Ambient Temperature and Humidity
Temperature Range
Relative Humidity
Max. Wet Bulb
Operational
10°C to 40°C
(35°C if only 1 PSU/
Cooling Module)
20% to 80%
non-condensing
23°C
Non-Operational
0°C to +60°C
8% to 80%
non-condensing
Shipping
-20°C to +60°C
5% to 100%
non-precipitating
Altitude
0 to 2133 m
Operational Shock
Vertical axis 5g peak 1/2 sine, 10ms
Operational Vibration
Random vibration power spectrum available on request
Non-Operational Shock
20g 20ms square wave
Acoustics
Free standing enclosure declared ‘A’ weighted sound power level
≤
6.8
Bels
Orientation & Mounting
19" Rack mount (4EIA Units)
• Rack Rails
To fit 800mm depth Racks compliant with IEC 297
• Rack Characteristics
Back pressure not exceeding 5 pascals (0.5mm water gauge)
Safety & Approvals
CE, UL, cUL
• EMC
EN55022 (CISPR - A), FCC A
Summary of Contents for Fibre Channel
Page 3: ...SS 1200 FCAL Rack Installation and User Guide Part No 19933 01 Issue 1 0 June 01 1998 ...
Page 22: ...SS 1200 FCAL User Guide 12 ...
Page 34: ...SS 1200 FCAL User Guide 24 ...
Page 48: ...SS 1200 FCAL User Guide 38 ...
Page 56: ...iv FCAL LRC I O Module ...
Page 66: ...FCAL LRC I O Module 8 ...
Page 69: ...SS 1200 FCAL Drive Carrier Module Installation Guide Part No 19935 01 Issue 1 0 June 01 1998 ...
Page 72: ...iv FC AL Drive Module ...
Page 82: ...FCAL Drive Module 8 ...