Getting Started
13
Chapter 2
Getting Started
2.1 Introduction
In this chapter, you are shown how to install your SS-1200-FCAL Enclosure and plug-in modules into an industry
standard 19 inch rack cabinet.
Caution
When connecting up the SS-1200-FCAL subsystem, use only approved power cords.
2.2 Planning Your Installation
Before you begin installation you should become familiar with the configuration requirements of your SS-1200-
FCAL system, detailed in
Table 2–1
. The correct positions of each of the optional plug-in modules are shown in
Figure 2–1
. Please refer to the accompanying FC-AL LRC I/O Module Installation Guide for details of FC-AL
configurations and installation.
Table 2–1 SS-1200-FCAL Configuration
Module Location
Drive Bays
ALL drive bays must be filled with either a drive carrier module, front dummy fascia
or (front) ESI/Ops Panel module (Bay 1/1 only), no bays should be left completely
empty.
Power Supply/Cooling
Modules
See Table 2-2
• Single Power Supply/Cooling module: if redundancy is NOT required and the
installed disk drives are low power, a single Power Supply/Cooling module must
always be fitted to rear Bay 2.
Single modules with a full compliment of drives will limit:
– the maximum operating temperature of the enclosure.
• Two Power Supply/Cooling modules: full power and cooling redundancy is
provided while a faulty module is replaced. Install the Power Supply/Cooling
modules in rear Bays 1 & 4. Refer to
Table 2–2
for details of limitations
• Three Power Supply/cooling Modules: full power and cooling redundancy with
high power drives is maintained while a faulty module is replaced. Install the
modules in bays 1, 2 and 4.
Summary of Contents for Fibre Channel
Page 3: ...SS 1200 FCAL Rack Installation and User Guide Part No 19933 01 Issue 1 0 June 01 1998 ...
Page 22: ...SS 1200 FCAL User Guide 12 ...
Page 34: ...SS 1200 FCAL User Guide 24 ...
Page 48: ...SS 1200 FCAL User Guide 38 ...
Page 56: ...iv FCAL LRC I O Module ...
Page 66: ...FCAL LRC I O Module 8 ...
Page 69: ...SS 1200 FCAL Drive Carrier Module Installation Guide Part No 19935 01 Issue 1 0 June 01 1998 ...
Page 72: ...iv FC AL Drive Module ...
Page 82: ...FCAL Drive Module 8 ...