20
A
RMING
I
NFORMATION
Delay Doors and Delay Time Settings
When the system is armed, enter and exit the premises only
through designated delay doors.
The time allowed to enter the premises and disarm the system is
the Entry Delay time.
The time allowed to leave the premises after arming the system is
the Exit Delay time.
P
AGING
For what events will the central station or pagers be notified?
Is the Streamlining feature enabled?
♦
Yes. When the system pages me, the message will not include
the central station account number. According to my pager
provider, the central station account number will appear as:
____________________________________________________
♦
No. All pages from my system will include the
account number.
I
F
THE
P
OWER
G
OES
O
UT
Your system has a backup battery that keeps your system opera-
tional during a power failure. An optional feature allows your sys-
tem to alert the central monitoring station if the power is off for
more than 15 minutes. It reports again when power has been
restored.
N
O
A
CTIVITY
T
IME
My system uses the No Activity feature.
♦
Yes. If there is no activity in my system for ____ hours (1-42,
default 24), the system will send a No Activity report to the
Central Station.
♦
No. My system setup does not include this feature.
S
YSTEM
I
NFORMATION
Door
Door Location
Entry
Delay
Exit
Delay
1
:
:
2
:
:
3
:
:
4
:
:
5
:
:
Feature
My system features include:
Quick Arm
♦
Yes. Press the arming level desired.
♦
No. Enter arming level, then access code.
Quick Exit
♦
Yes. Press
D
and exit your armed premises
through a delay door within 2 minutes.
♦
No. I need to disarm my system in order to
exit the premises.
Exit Extension
♦
Yes. If I re-enter the armed premises during
the Exit Delay time, the Exit Extension will
begin.
♦
No. If I re-enter the armed premises during
the Exit Delay time, it will continue to count
down and I must disarm the system.
Keyswitch
Arming
♦
Yes. I can use a key to arm the system.
The switch is located:
______________________________________
______________________________________
♦
No.
Auto STAY
Arming
♦
Yes. If, after arming to Level 3—AWAY, I don’t
exit through a designated delay door, the sys-
tem will arm to Level 2—STAY.
♦
No. If, after arming to Level 3—AWAY, I don’t
exit through a designated delay door, the sys-
tem will continue to arm to Level 3—AWAY.
And, if my system contains motion detectors,
movement may cause an alarm.
CS 1
CS 2
Pagers
Reporting Features
1
2
3
High Level Reports
Low Level Reports
Opening/Closing Reports
Latchkey Reports
N/A
N/A
System Information
Code
Factory code
System number
System level