TELEPHONE PAGING
5
TP-6231
5. SERIAL CONTROL and COMMANDS)
Serial Communication type: 1stop bit, non-parity, 8bits data, 9600 bps.
CONTROL COMMANDS (If serial communication terminal is used)
TP-6231 enables each commends.
6. Address Setting
1) ECS-6216P / RME-6108
If connected with ECS-6216P or RME-6108, set address number for proper connection conditions.
2) When connecting to ECS-6216P directly (Can also be used with RM-6024)
- If Connected to RM1 terminal of ECS-6216P set address number of TP- 6231 to 1.
- If Connected to RM2 terminal of ECS-6216P set address number of TP- 6231 to 9.
CHANNEL
1. START CODE
2. SET
3. Command types
4. Operation commands
5. CHANNEL Number
6. SPACE
CHANNEL 1
54Hex
60Hex + SET Number (Top 4BITS: MSB)
70Hex + SET Number (Sub 4BITS: LSB)
50Hex + Type of Number
23Hex : ON, 26Hex : OFF
30 - 3FHex
FFHex
REMARK
SET number equal to the area code (01 - FFH)
50Hex=ALL, 51Hex=GROUP, 52H=EACH
23Hex : When you choosing broadcast local
26Hex : HOOK-OFF
Select CHANNEL 1-16
END CODE
RM1
INPUT
AUDIO
OUT
AUDIO
OUT
RM2
INPUT
ECS-6216P
RM1 RM2
TP-6231 or RM-6024
TP-6231 or RM-6024
Address No:
select 9
Address No:
select 1