1.800.737.5386 • www.Inter-Fab.com
9
PROGRAMMING A NEW TRANSMITTER TO THE RECIEVER
*Note
– The Transmitter will be programmed to the lift when you receive it; the only time you will have to
follow this procedure is if you replace a Transmitter or buy an extra Transmitter.
To Program a new transmitter to the lift, first remove the battery from the lift. Hold the lockout button on the
transmitter for two full seconds. Then press and hold the up button on the Transmitter to be programmed, while
replacing the battery on the lift. Continue holding the up button on the Transmitter until the lift clicks once or
moves up (the lift is most likely at the top of its range, so you may try either rotation button and watch for lift
movement). If the lift does not work with the new transmitter, try the procedure again; making sure that the
transmitter is unlocked. If you are not able to program the new Transmitter to your lift, please call Inter-Fab
Customer Service at 1-800-737-5386 ext 121.
BATTERY CHARGING & INSTALLATION
The battery comes fully charged, but will need charging after the first several hours of use. Charging time is
approximately twelve hours for the first few charges, six hours after the first four battery cycles at which point the
battery will reach maximum capacity. The i-Lift comes with a battery charger, bracket, and a spacer for wall
mounting (in a dry location). For wall mounting, use three #8 or #10 wall anchors spaced 5 ½-inches apart
(vertically). Charge the battery as follows:
Plug the battery charger into a standard*
outlet. The green LED on the charger will light up, indicating
that the charger is on.
Slide the battery onto the bracket and onto the charger. The green LED will change to yellow, indicating
that the battery is being charged. If the battery is very low the LED will be red, if the red LED does not
change to yellow within 4 hours, the battery is bad.
The yellow LED will turn Green when the battery is fully charged. You will prolong the life of your charger
if you disconnect the battery after 24 hours of charging time.
Unplug the charger when it is not connected to the battery, if it is left plugged in for an extended period of
time while not charging a battery, damage to the charger may occur.
*Charger accepts 110 VAC