Page 50
Intepro Systems
www.inteproate.com
PS 9000 3U Series
Element
Description
DC output after OT alarm
Determines how the DC output shall react after an overtemperature alarm has
occurred:
•
OFF
= DC output will be switched off and remain until user action
•
AUTO
= DC output will switch on again after the device has cooled down and if
the output has been switched on before the alarm occurred
Share Bus mode
Default setting:
Slave
For parallel operation of multiple units, where using the Share bus connection is
recommended. In parallel operation, every unit could be
Master
or
Slave
, but only
one must be
Master
.
3.4.3.2
Menu “Calibrate Device”
From within this menu, a calibration and readjustment procedure for output voltage and current can be started.
For further details refer to
„4.3. Calibration (readjustment)“
.
Element
Description
Voltage calibration
Starts the semi-automatic calibration procedure for output voltage U
Sense volt. calibration
Starts the semi-automatic calibration procedure for remote sensing input „Sense“
Current calibration
Starts the semi-automatic calibration procedure for output current I
Set calibration date
Here you can enter the date of the most recent calibration (year, month, day)
Save and exit
This menu item saves and leaves the setup menu to main display
3.4.3.3
Menu “Reset Device”
Entering this menu item will prompt for acknowledgement to reset the device completely to default settings and
set values. Selection “
No
” will cancel the reset procedure, while selection “
Yes
”, submitted by
button, will
instantly reset the device.
3.4.3.4
Menu “Profiles”
See
„3.8 Loading and saving a user profile“ on page 63.
3.4.3.5
Menus “Overview” and “About HW, SW...”
This menu pages display an overview of the set values (U, I, P) and related protection settings (OVP, OCP, OPP)
as well as limits settings and an alarm history (counter) of alarms that might have occured since the last time the
unit was switched on. Furthermore they show device relevant data such as serial number, article number etc.
3.4.3.6
Menu “Communication”
Here settings for the Ethernet port (on rear side of device, only available with standard models) or the optional
GPIB port are made. The USB port there doesn’t require any settings. When delivered or after a complete reset,
the Ethernet port has following
default settings
assigned:
•
DHCP: off
•
IP: 192.168.0.2
•
Subnet mask: 255.255.255.0
•
Gateway: 192.168.0.1
•
Port: 5025
•
DNS: 0.0.0.0
•
Host name: Client
•
Domain: Workgroup
Those settings can be changed anytime and configured to meet local requirements. Furthermore, there are global
communication settings available regarding timing and protocols.