Page 16
Intepro Systems
www.inteproate.com
PS 9000 3U Series
15 kW
Model 400 V
PS 9200-210 PS 9360-120 PS 9500-90
PS 9750-60
PS 91500-30
AC Input
Voltage (L-L)
340...460 V AC, 45 - 65 Hz
Input connection
3ph,PE
Input fuse (internal)
6x T16 A
Leak current
< 3.5 mA
Power factor
> 0.99
DC Output
Max. output voltage U
Max
200 V
360 V
500 V
750 V
1500 V
Max. output current I
Max
210 A
120 A
90 A
60 A
30 A
Max. output power P
Max
15 kW
15 kW
15 kW
15 kW
15 kW
Overvoltage protection range
0...220 V
0...396 V
0...550 V
0...825 V
0...1650 V
Overcurrent protection range
0...231 A
0...132 A
0...99 A
0...66 A
0...33 A
Overpower protection range
0…16.5 kW
0…16.5 kW
0…16.5 kW
0…16.5 kW
0…16.5 kW
Temperature coefficient for set
values Δ/K
Voltage / current: 100 ppm
Output capacitance (approx.)
7560 μF
1200 μF
760 μF
310 μF
84 μF
Voltage regulation
Adjustment range
0...204 V
0...367.2 V
0...510 V
0...765 V
0...1530 V
Accuracy
(1
(at 23±5°C / 73±9°F))
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
Line regulation at ±10% ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Load regulation at 0...100% load
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Rise time 10...90%
Max. 30 ms
Max. 30 ms
Max. 30 ms
Max. 30 ms
Max. 30 ms
Settling time after load step
< 2 ms
< 2 ms
< 2 ms
< 2 ms
< 2 ms
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
Ripple
(2
< 300 mV
PP
< 40 mV
RMS
< 550 mV
PP
< 65 mV
RMS
< 350 mV
PP
< 70 mV
RMS
< 800 mV
PP
< 200 mV
RMS
< 2400 mV
PP
< 400 mV
RMS
Remote sensing compensation
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Fall time at no load after switching
DC output off
Down from 100% to <60 V: less than 10 s
Current regulation
Adjustment range
0...214.2 A
0...122.4 A
0...91.8 A
0...61.2 A
0...30.6 A
Accuracy
(1
(at 23±5°C / 73±9°F))
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
Line regulation at ±10% ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Load regulation at 0...100% ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 66 mA
RMS
< 15.6 mA
RMS
< 48 mA
RMS
< 48 mA
RMS
< 26 mA
RMS
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
Power regulation
Adjustment range
0…15.3 kW
0…15.3 kW
0…15.3 kW
0…15.3 kW
0…15.3 kW
Accuracy
(1
(at 23±5°C / 73±9°F))
< 1% P
Max
< 1% P
Max
< 1% P
Max
< 1% P
Max
< 1% P
Max
Line regulation at ±10% ΔU
AC
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
Load reg. at 10-90% ΔU
OUT
* ΔI
OUT
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.8% P
Max
≤ 0.85% P
Max
≤ 0.85% P
Max
≤ 0.85% P
Max
≤ 0.85% P
Max
Efficiency
(3
≈ 95%
≈ 94%
≈ 95%
≈ 94%
≈ 95%
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display error adds to the error of the related actual value on the DC output