
Page 49
Intepro Systems
www.inteproate.com
PS 9000 3U Series
3.4.3.1
Menu “General Settings”
Element
Description
Allow remote control
Selection “NO” means that the device can’t be remotely controlled over any of the
digital or analog interfaces. If remote control isn’t allowed, the status will be shown
as “
Local
” in the status area on the main display. Also see section
1.9.6.1
Analog interface range
Selects the voltage range for the analog set input values, actual output values and
reference voltage output of the analog interface on the rear.
•
0...5 V
= Range is 0...100% set /actual values, reference voltage 5 V
•
0...10 V
= Range is 0...100% set /actual values, reference voltage 10 V
See also section
„3.4.3. Configuration in the setup menu“
Analog interface Rem-SB
Determines with “
Normal
” (default), that the function and levels of input Rem-SB
are as described in
„3.5.4.4. Analog interface specification“
. With selection “
invert-
ed
”, the described function is logically inverted. Also see example a) in
„3.5.4.7.
Application examples“
.
Analog interface pin 6
Pin 6 of the analog interface (see section
3.5.4.4
) is by default assigned to only signal
the device alarms OT and PF. This parameter allows to also enable signaling only
one of both (3 possible combinations):
OT
= Enable/disable signaling of alarm OT on pin 6
PF
= Enable/disable signaling of alarm PF on pin 6
Analog interface pin 14
Pin 14 of the analog interface (see section
3.5.4.4
) is by default assigned to only
signal the device alarm OVP. This parameter allows to also enable signaling further
device alarms (7 possible combinations):
OVP
= Enable/disable signaling of alarm OVP on pin 14
OCP
= Enable/disable signaling of alarm OCP on pin 14
OPP
= Enable/disable signaling of alarm OPP on pin 14
Analog interface pin 15
Pin 15 of the analog interface (see section
3.5.4.4
) is by default assigned to only
signal the regulation mode CV. This parameter allows to enable signaling a different
device status (2 options):
Regulation mode
= Enable/disable signaling of CV reg mode on pin 15
DC status
= Enable/disable signaling of DC output status on pin 15
Analog Rem-SB action
Since Firmware 2.03, the input REM-SB of the analog interface can be used to
control the DC output of the device even without remote control via analog interface
being activated. This setting determines the type of action:
•
DC
OFF
= Toggling the pin only switches the DC output off
•
DC ON/OFF
= If the DC output has been switched on before, toggling the pin
can switch the output off and on again
DC output after power ON
Determines the condition of the DC output after power-up.
•
OFF
= DC output is always off after switching on the device.
•
Restore
= DC output condition will be restored to the condition prior to switch off.
DC output after PF alarm
Determines how the DC output shall react after a power fail (PF) alarm has
occurred:
•
OFF
= DC output will be switched off and remain until user action
•
AUTO
= DC output will switch on again after the PF alarm cause is gone and if
it was switched on before the alarm occurred
DC output after remote
Determines the condition of the DC output after leaving remote control either man
-
ually or by command.
•
OFF
= DC output will be always off when switching from remote to manual
•
AUTO
= DC output will keep the last condition
Summary of Contents for 06230250
Page 2: ......