Page 14
Intepro Systems
www.inteproate.com
PS 9000 3U Series
10 kW / 15 kW
Model 400 V
PS 9360-80
PS 9500-60
PS 9750-40
PS 91000-30 PS 9080-510
AC Input
Voltage (L-L)
340...460 V AC, 45 - 65 Hz
Input connection
3ph,PE
Input fuse (internal)
4x T16 A
Leak current
< 3.5 mA
Power factor
> 0.99
DC Output
Max. output voltage U
Max
360 V
500 V
750 V
1000 V
80 V
Max. output current I
Max
80 A
60 A
40 A
30 A
510 A
Max. output power P
Max
10 kW
10 kW
10 kW
10 kW
15 kW
Overvoltage protection range
0...396 V
0...550 V
0...825 V
0...1100 V
0...88 V
Overcurrent protection range
0...88 A
0...66 A
0...44 A
0...33 A
0...561 A
Overpower protection range
0…11 kW
0…11 kW
0…11 kW
0…11 kW
0…16.5 kW
Temperature coefficient for set
values Δ/K
Voltage / current: 100 ppm
Output capacitance (approx.)
800 μF
500 μF
210 μF
127 μF
25380 μF
Voltage regulation
Adjustment range
0...367.2 V
0...510 V
0...765 V
0...1020 V
0...81.6 V
Accuracy
(1
(at 23±5°C / 73±9°F))
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
Line regulation at ±10% ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Load regulation at 0...100% load
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Rise time 10...90%
Max. 30 ms
Max. 30 ms
Max. 30 ms
Max. 30 ms
Max. 30 ms
Settling time after load step
< 1.5 ms
< 1.5 ms
< 1.5 ms
< 1.5 ms
< 2 ms
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
≤ 0.2% U
Max
Ripple
(2
< 550 mV
PP
< 65 mV
RMS
< 350 mV
PP
< 70 mV
RMS
< 800 mV
PP
< 200 mV
RMS
< 1600 mV
PP
< 350 mV
RMS
< 320 mV
PP
< 25 mV
RMS
Remote sensing compensation
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Fall time at no load after switching
DC output off
Down from 100% to <60 V: less than 10 s
Current regulation
Adjustment range
0...81.6 A
0...61.2 A
0...40.8 A
0...30.6 A
0...520.2 A
Accuracy
(1
(at 23±5°C / 73±9°F))
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
Line regulation at ±10% ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Load regulation at 0...100% ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 10.4 mA
RMS
< 32 mA
RMS
< 32 mA
RMS
< 22 mA
RMS
< 240 mA
RMS
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
≤ 0.2% I
Max
Power regulation
Adjustment range
0…10.2 kW
0…10.2 kW
0…10.2 kW
0…10.2 kW
0…15.3 kW
Accuracy
(1
(at 23±5°C / 73±9°F))
< 1% P
Max
< 1% P
Max
< 1% P
Max
< 1% P
Max
< 1% P
Max
Line regulation at ±10% ΔU
AC
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
Load reg. at 10-90% ΔU
OUT
* ΔI
OUT
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max
Display: Resolution
See section
„1.9.6.4. Resolution of the displayed values“
Display: Accuracy
(4
≤ 0.8% P
Max
≤ 0.85% P
Max
≤ 0.85% P
Max
≤ 0.85% P
Max
≤ 0.8% P
Max
Efficiency
(3
≈ 93%
≈ 95%
≈ 94%
≈ 95%
≈ 93%
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display error adds to the error of the related actual value on the DC output