NSN 6130-99-391-3441 ()
Battery Charger Analyser : Operator Manual
12.1 Creating Lead Acid (Pb) Library Entry
N E W C U S T O M B A T T E R Y : S E L E C T T Y P E
P B
Press
B A T T E R Y N O M I N A L V O L T A G E 0 . 0 V
Type the batteries nominal voltage and
C A P A C I T Y T E S T
E N D V O L T S
0 . 0 V
A M P S x x . x A T I M E x x . x H
Type the termination voltage then
followed by the test current then
then the
test duration (usually 1.0H) followed by
.
P b C V C H A R G E
V O L T S
0 . 0 V M A X A M P S x x . x A T I M E x x . x H
Type the constant voltage charge value followed by
then the current limit amps then
and the max charge duration and
P b C V C H A R G E
M I N A M P S 0 . 0 0 A C H O V E R x x . x A C T H S H x x . x A
Type the end of charge minimum current followed by
the current potential
changeover and
the current threshold amps and
P b C C C H A R G E
C H R G A M P S 0 . 0 A M A X V O L T S x x . x V
Type the constant current amps and
then the max volts and
. The battery
charger will then display the following:
E N T R Y W R I T T E N T O M E M O R Y
Doc: DWG1030-25-R11 Operators manual.odt
Page 38 of 72
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 12/06/17