Chapter 6 - Using Passive Infrared Sensors

 

 

B.

 

 Infrared Signal:

 

 

The optimum signal produced by a human is at a distance of 20 feet for the 

IR-301, with the person walking at a casual pace (3 ft./sec).  This is strictly 
a function of the sensor’s optics, which is fixed and determines the devices 

beam spread (4 ft. @ 20 ft. for the IR-301).  At 20 feet, a person completely 
fills the sensing region of each beam causing a maximum signal.  Further 

away than 20 feet, the person only partially fills the sensing region, thereby 
generating a smaller signal.  Closer than 20 feet, the person passes through 

the beams faster since they are closer together, likewise generating a 
smaller signal.

 

 

Therefore a person running by the sensor at 10 feet may register the same 

as a person walking by at 30 feet, neither being sufficient to trip the sensor.  
Automobiles will likewise be difficult to detect when the sensor is mounted 

close to the road and they are moving fast.  To compensate, you can either 
move the sensor back from the road (fifty feet is OK) or you can aim the 

sensor using a slight 70 degree angle, which in effect causes the sensor 
beam geometry to widen.  This will give much better results, especially if the 

sensor is aimed upstream, since the target will be detected sooner.  Also, 
the RF transmission range between sensor and receiver should be kept 

short, which will improve the overall reliability.

 

 

C.

 

 Infrared Noise:

 

 

Infrared Noise includes all environmental disturbances that occur when the 
sensor is not detecting a target, such as wind chill on stationary objects or 

blowing tree leaves on moving objects.  Much of these types of disturbance 
are filtered out by the side-by-side orientation of the infrared beams.  Thus, 

heat rising from a blacktop road will hit both beams simultaneously, causing 
a cancellation of their signals.  However, under certain circumstances, a tree 

branch moving back and forth as the wind blows can look like a person doing 
the same thing.  This can really be a problem if the sensor is aimed at the 

solid surface, which is relatively warm due to sunlight, and the cooler leaves 
from a branch are blowing in front of the Sensor.  A blade of grass located a 

few inches from the sensor, blowing in the wind, can also appear as a person 
walking, again because of the smaller beam geometry at that distance.

 

 

To prevent unwanted false alarms or reduced sensor performance, the 

sensor should always be located on a stationary object (large tree trunk), 
which will not move when the wind blows (avoid smaller diameter trees).  

Any offending grasses or branches should always be pruned away from the 
sensor’s field of view.  Avoid aiming the sensor at trees with moving 

branches, especially at close distances (less than 10 feet).

 

 

Summary of Contents for PPK-3 KIT

Page 1: ...1 PPK 3 KIT Perimeter Protection Kit DocRef 0100601 PPK 3 Kit User Guide Revised 2016 8 2 ...

Page 2: ...Troubleshooting Page 5 A Low Batteries B Limited RF Signal Reception C No Audible Beep Section 2 IR 301 Passive Infrared Sensor A Introduction Page 6 B Product View and Description Page 6 Section 3 Using Passive Infrared Sensors A Introduction Page 8 B Infrared Signal Page 9 C Infrared Noise Page 9 Section 4 Appendix A Technical Specifications Page 10 B RF Interference Page 11 C Contact Informatio...

Page 3: ...y receive alarms from the PPK s IR 301 s sensors and not with other standard Intellicam sensors B Product View 1 Power Slide Switch 2 SMA Antenna Connection 3 Headphone Jack 4 Playback Button 5 Red and Green LED Lights C Standard Accessories 1 SMA Stainless Antenna 2 Earbud Headphones not pictured 3 Beeper Module Beeper Module Slide Switch Red Green LEDs Playback Button SMA Antenna ...

Page 4: ... in the desired device into the Headphone Jack B Power On Off 1 Slide the Power Slide Switch on the top panel to the desired position 2 Always remember to turn the PPK 3A to the Off position after use to conserve battery life II Alarm and Playback A Alarm 1 New Alarm When a new sensor alarm occurs the PPK 3A will notify the Operator of the corresponding Sensor ID Number The PPK 3 will indicate the...

Page 5: ...ecurely attached to SMA connector 2 Interference from surroundings such as bushes trees or walls may be blocking RF signal to the PPK 3A Receiver Optional antennas may increase reception C No Audible Beep 1 The problem may be the Headphone Jack First check both the Beeper Module and the Earbud Headphones to ensure that these devices are working properly It is not recommended to use any other Headp...

Page 6: ...nsor ID s of 1 through 4 and a fixed Sensor Sensitivity of 3 The PPK 3 Kit is designed for perimeter protection The Operator can locate the four IR 301 sensors with unique Sensor ID s of 1 2 3 and 4 around the perimeter and record the sensor locations on the site plan If a Sensor is triggered it will send a wireless RF signal to the PPK 3A receiver letting the Operator know the exact location of t...

Page 7: ...t only illuminates when an alarm occurs during the first 10 minutes to aid in the initial set up and will automatically turn off after 10 minutes for covert reasons Antenna The flexible stainless ANTENNA allows for the UHF propagation of the RF signal The ANTENNA must be oriented in a vertical direction for best RF propagation and for proper alignment of the infrared beams Lens The IR 301 s focal ...

Page 8: ...se ratio The signal corresponds to whatever it is we are interested in detecting be it a bird a human an automobile or an airplane which all have different sizes shapes and travel at different speeds As far as the IR 301 is concerned they will all result in a different signal or infrared signature when the IR 301 sees them This will involve placing the sensor at a certain distance and orientation ...

Page 9: ...er Also the RF transmission range between sensor and receiver should be kept short which will improve the overall reliability C Infrared Noise Infrared Noise includes all environmental disturbances that occur when the sensor is not detecting a target such as wind chill on stationary objects or blowing tree leaves on moving objects Much of these types of disturbance are filtered out by the side by ...

Page 10: ...ation OOK 2 4Khz RF Frequency 916 5 MHz SAW stabilized Field of View 15 degrees Dimensions 1 0 dia x 2 8 length Weight 1 8 oz 45g PPK 3A Receiver Processor Specifications Battery Type 3 each AAA 1 5 VDC Lithium Batteries Power Supply Current Normal Operating 2 5 milliamps Sleep Mode 300 micro amps Operating Temperature 14 F to 122 F 10 C to 50 C Frequency 916 5 MHz SAW stabilized Sensitivity 98 db...

Page 11: ...nge 100 ft due to the fact that the FCC restricts the power output at this frequency Although the Receiver Processor will reject most of this interference it is best to locate the interfering source and remove it if possible prior to doing installation or degraded reliability could result WARNING This device operates under Part 15 of the FCC Rules Any modification not expressly approved by Intelli...

Reviews: