![Intelix DIGI-88FS Installation And Operation Manual Download Page 23](http://html1.mh-extra.com/html/intelix/digi-88fs/digi-88fs_installation-and-operation-manual_2073647023.webp)
DIGI-88FS Installation Guide
23
RS232 Commands
Default RS232 settings:
19200 baud, 8 Data bits, 1 Stop bit, Parity = None
There are no spaces between any of the characters in the command string.
i
= Input Command
xx
= Input Number (input 2 would be 02)
o
= Output Command
yy
= Output Number (output 3 would be 03)
*
= All output ports
<CR>
= Carriage Return (Hex 0D)
<LF>
= Line Feed (Hex 0A)
After entering a command, a verification message appears at the end of the command line as follows:
Command OK
: indicates the command is correct and successfully executed by the matrix
Command Incorrect
: indicates the command has the wrong format and/or values.
Routing Commands
AV Muting Commands
Description
Command
Route input
xx
to output
yy
swi
xx
o
yy
<CR><LF>
Route input
xx
to all outputs
swi
xx
o*<CR><LF>
Next input on output
yy
swo
yy
+<CR><LF>
Previous input on output
yy
swo
yy
-<CR><LF>
Example
Command
Route input
1
to output
7
swi
01
o
07
<CR><LF>
Description
Command
Turn on audio output
yy
muteo
yy
off<CR><LF>
Turn off audio output
yy
muteo
yy
on<CR><LF>
Turn on video output
yy
swo
yy
on<CR><LF>
Turn off video output
yy
swo
yy
off<CR><LF>
Turn on all video outputs
swo*on<CR><LF>
Turn off all video outputs
swo*off<CR><LF>
Example
Command
Turn on audio output
3
muteo
03
off<CR><LF>
Turn off video output
4
swo
04
off<CR><LF>
Summary of Contents for DIGI-88FS