background image

 

INTELCO ELECTRONICS                                

10

   

            ISO9001/2008      

Rev. 1.00  January 2015 

Supervisor Password 

If there is no possibility of using the admin password you should contact your retailer. 
The retailer will ask the Serial Number of the device, which will be used, after identification 
of the owner, in an algorithm that will generate Supervisor Password. 

 

Programming Supervisor Password: 

While device is powered up Supervisor password must be typed according the below way. 

 

 

 

 

 

After code typed well device will response with 5 short buzzer sounds (150 ms pause      
between each other) 

 
There is always the possibility to return the device to the factory for reprogramming the  
factory settings (Factory Reset).  

XXXX 

Retailer given 

number 

Summary of Contents for INTD1001/1

Page 1: ...Keylock Please read the instructions carefully in order to get all of the benefits of this device Page 2 General description Page 3 Features Specifications Page 4 Wiring Page 5 Operation Page 6 7 Pro...

Page 2: ...ight Relay commands INTD1001 S With one Relay and serial communication with extension device INTD1001 E8 Extension device 8 Relays with serial communications General Description Dear customer Thank yo...

Page 3: ...delay for each relay Latch mode supported for each relay False password Detect and Lock function Features Power supply 12 to 24 V DC AC Power consumption 0 3mA with 8 relay enabled Security Levels Us...

Page 4: ...s from relays to control panel and then power on see Schematic 1 After Keylock is properly powered you will here a short sound 500ms and then device is ready to use Wiring Connection Power Supply CAUT...

Page 5: ...e pressed key 1 8 will release the relay too Act as Password Protected Relay After programming and enable one of Relay 1 8 working as Password Protected Relay then any action referred to this Key it w...

Page 6: ...ill be enabled Enable Password While desired relay password is disabled set 000 as User Old password Factory preset password and set any desired password at User New password Ex 653 Note Factory prese...

Page 7: ...ssword Relay Programming Latch Mode Programming latch mode requires selected relay being in Password Protected Relay function Every Password Protected Relay act in 2 ways Latch Off Timer Latch On Latc...

Page 8: ...Time is 2 seconds 02 99 877 Latch On code Relay Current User password of Relay Buzzer Sounds Buzzer helps the human interacts with the device in order to understand the process has been made in every...

Page 9: ...strator Password While device is powered up administrator can handle is password according the below way Note Factory preset Admin password is 0000 0000 3546 Admin Old password Admin New password Rese...

Page 10: ...entification of the owner in an algorithm that will generate Supervisor Password Programming Supervisor Password While device is powered up Supervisor password must be typed according the below way Af...

Reviews: