     The dial keypad INTD1001, with its multitude of different functions which are inte-
grated in its program, can be used in elevators for access control to private floors, such 
as office buildings and apartments.  

The device INTD1001 is offered in a range of models to cover the needs of the customer 
at the lowest possible cost. 
Model series: 
INTD1001 / 1: One Relay command. 
INTD1001 / 2: Two Relay commands. 
INTD1001 / 4: Four Relay command. 
INTD1001 / 8: Eight Relay commands. 
INTD1001 / S: With one Relay and serial communication with extension device. 
INTD1001 / E8: Extension device 8 Relays with serial communications. 

General Description:  

     Dear customer, 
Thank you for choosing one of  INTELCO Electronics products. 
Intelco Electronics is studying and producing products the last 30 years, always applying 
the latest developments, in the international market of electronic and lifts. 
Intelco Electronics with continuous presence in international exhibitions, promotes its prod-
ucts in the international market having stable network customers in most countries of the 
European Union. 
People of  INTELCO thank you and will always be there for any technical support. 

Summary of Contents for INTD1001/1

Page 1: ...Keylock Please read the instructions carefully in order to get all of the benefits of this device Page 2 General description Page 3 Features Specifications Page 4 Wiring Page 5 Operation Page 6 7 Pro...

Page 2: ...ight Relay commands INTD1001 S With one Relay and serial communication with extension device INTD1001 E8 Extension device 8 Relays with serial communications General Description Dear customer Thank yo...

Page 3: ...delay for each relay Latch mode supported for each relay False password Detect and Lock function Features Power supply 12 to 24 V DC AC Power consumption 0 3mA with 8 relay enabled Security Levels Us...

Page 4: ...s from relays to control panel and then power on see Schematic 1 After Keylock is properly powered you will here a short sound 500ms and then device is ready to use Wiring Connection Power Supply CAUT...

Page 5: ...e pressed key 1 8 will release the relay too Act as Password Protected Relay After programming and enable one of Relay 1 8 working as Password Protected Relay then any action referred to this Key it w...

Page 6: ...ill be enabled Enable Password While desired relay password is disabled set 000 as User Old password Factory preset password and set any desired password at User New password Ex 653 Note Factory prese...

Page 7: ...ssword Relay Programming Latch Mode Programming latch mode requires selected relay being in Password Protected Relay function Every Password Protected Relay act in 2 ways Latch Off Timer Latch On Latc...

Page 8: ...Time is 2 seconds 02 99 877 Latch On code Relay Current User password of Relay Buzzer Sounds Buzzer helps the human interacts with the device in order to understand the process has been made in every...

Page 9: ...strator Password While device is powered up administrator can handle is password according the below way Note Factory preset Admin password is 0000 0000 3546 Admin Old password Admin New password Rese...

Page 10: ...entification of the owner in an algorithm that will generate Supervisor Password Programming Supervisor Password While device is powered up Supervisor password must be typed according the below way Af...