Troubleshooting
Intel® Carrier Grade Server TIGI2U User Guide
97
BIOS Error Messages
When a recoverable error occurs during the POST, the BIOS displays an error message
describing the problem.
Table 6. BIOS Error Messages
Error Message
Explanation
GA20 Error
An error occurred with Gate A20 when switching to protected mode
during the memory test.
Pri Master HDD Error
Pri Slave HDD Error
Sec Master HDD Error
Sec Slave HDD Error
Could not read sector from corresponding drive.
Pri Master Drive - ATAPI Incompatible
Pri Slave Drive - ATAPI Incompatible
Sec Master Drive - ATAPI Incompatible
Sec Slave Drive - ATAPI Incompatible
Corresponding drive is not an ATAPI (Advanced Technology
Attachment Packet Interface) device. Run Setup to make sure
device is selected correctly.
A: Drive Error
No response from diskette drive.
CMOS Battery Low
The battery may be losing power. Replace the battery soon.
CMOS Display Type Wrong
The display type is different from what has been stored in CMOS.
Check Setup to make sure type is correct.
CMOS Checksum Bad
The CMOS checksum is incorrect. CMOS memory may have been
corrupted. Run Setup to reset values.
CMOS Settings Wrong
CMOS values are not the same as the last boot. Either these
values have been corrupted or the battery has failed.
CMOS Date/Time Not Set
The time and/or date values stored in CMOS are invalid. Run
Setup to set correct values.
DMA Error
Error during read/write test of DMA (Direct Memory Access)
controller.
FDC Failure
Error occurred trying to access diskette drive controller.
HDC Failure
Error occurred trying to access hard disk controller.
Checking NVRAM.....
NVRAM (Non-Volatile Random Access Memory) is being checked
to see if it is valid.
Update OK!
NVRAM was invalid and has been updated.
Updated Failed
NVRAM was invalid but was unable to be updated.
Keyboard Error
Error in the keyboard connection. Make sure keyboard is
connected properly.
KB/Interface Error
Keyboard interface test failed.
continued