Intel
®
Server System SR2600UR/SR2625UR Service Guide
145
Appendix A:
Technical Reference
750-W Single Power Supply Input Voltages
The power supply must operate within all specified limits over the input voltage range
shown in the following table.
Table 5. Power Supply Input Voltages
Notes:
1. Maximum input current at low input voltage range is measured at 90 VAC, at
maximum load.
2. Maximum input current at high input voltage range is measured at 180 VAC, at
maximum load.
3. This is not to be used for determining agency input current markings.
4. Maximum rated input current is measured at 100 VAC and 200 VAC.
750-W Single Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each
voltage. Ensure that your loads do not exceed the combined total wattage of 750 Watts
Parameter
Minimum
Rated
Maximum
Startup VAC
Power-off
VAC
Maximum
Input AC
Current
Maximum
Rated Input
AC Current
Voltage
(110)
90 V
rms
100-127
V
rms
140 V
rms
85 VAC +/-
4 VAC
75 VAC +/-
5 VAC
12 A
rms
1,3
11.0 A
rms
4
Voltage
(220)
180 V
rms
200-240
V
rms
264 V
rms
6.0 A
rms
2,3
5.5 A
rms
4
Frequency
47 Hz
50/60 Hz
63 Hz
Table 6. Power Supply Output Capability
Voltage
Minimum OCP Limits
Maximum OCP Limits
+3.3 V
110% (= 26.4 A)
150% (= 36 A)
+5.0 V
110% (= 33 A)
150% (= 45 A)
Summary of Contents for SR2600URLX
Page 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Page 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Page 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Page 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Page 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Page 170: ...152 Intel Server System SR2600UR SR2625UR Service Guide...
Page 180: ...162 Intel Server System SR2600UR SR2625UR Service Guide...
Page 204: ...186 Intel Server System SR2600UR SR2625UR Service Guide...
Page 228: ...210 Intel Server System SR2600UR SR2625UR Service Guide...