Environmental Specifications
Intel® Server Board S5500HV/Intel® Server System SR1670HV TPS
Revision 1.2
Intel Confidential
60
Intel order number E69391-006
Note
: Intel
®
Server Systems processor support is limited to 95W TDP power.
9.3
Intel
®
Server System SR1670HV Environmental Specifications
The operation of the server system at conditions beyond those shown in the following table may
cause permanent damage to the system. Exposure to absolute maximum rating conditions for
extended periods may affect system reliability
Table 27. Server System Environmental Limits Summary
Parameter
Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating
Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing at 35°C
Acoustic noise
Idle = 67.3 dBA
Active = 73.5 dBA
Shock, operating
Half sine, 2 g peak, 11 milliseconds
Shock, unpackaged
Trapezoidal, 25 g, velocity change 136 inches/second (
≧
40 lbs to < 80 lbs)
Shock, packaged
Non-palletized free fall in height 24 inches (
≧
40 lbs to < 80 lbs)
Vibration, unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
Shock, operating
Half sine, 2 g peak, 11 milliseconds
ESD
+/-15 KV except I/O port +/- 8 KV per Intel
®
Environmental test specification
System Cooling
Requirement in BTU/Hr
2550 BTU/hour
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Disclaimer Note
: Intel Corporation server boards contain a number of high-density VLSI and
power delivery components that need adequate airflow to cool. Intel ensures through its own
chassis development and testing that when Intel server building blocks are used together, the
fully integrated system will meet the intended thermal requirements of these components. It is
the responsibility of the system integrator who chooses not to use Intel developed server
building blocks to consult vendor datasheets and operating parameters to determine the amount
of airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible, if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
9.4
Processor Power Support (Integrated System)
Thermally, the Intel Server System SR1670HV can support a maximum Thermal Design Power
(TDP) rating of 95 Watts for Intel
®
Xeon
®
processor 5500 series and 5600 series.