Intel® Server Board S5500HV/Intel® Server System SR1670HV TPS
Platform Management
29
Intel Confidential
Revision 1.2
Intel order number E69391-006
Table 8. System Sensors
System Sensor Table
No
Sensor Name
Sensor Type
Sensor
Type
code
Event Type
MLED
30h
Reserved
31h
CPU1 Temperature
Temperature
01h
01h
01h
01h
01h
01h
01h
01h
01h
01h
01h
01h
01h
Threshold (01h)
00h:Lower Non-critical - going low
01h:Lower Non-critical - going high
02h:Lower Critical - going low
03h:Lower Critical - going high
04h:Lower Non-recoverable - going low
05h:Lower Non-recoverable - going high
06h:Upper Non-critical - going low
07h:Upper Non-critical - going high
08h:Upper Critical - going low
09h:Upper Critical - going high
0Ah:Upper Non-recoverable - going low
0Bh:Upper Non-recoverable - going high
UC, UNC
UC
32h CPU2
Temperature
Temperature
01h
Threshold (01h)
UC, UNC
UC
cch TR1
Temperature
Temperature
01h
Threshold (01h)
UC, UNC
UC
cdh TR2
Temperature Temperature
01h
Threshold (01h)
UC, UNC
UC
34h
VCORE1 Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
35h
VCORE2 Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
36h
+3.3V Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
37h
+5V Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
38h
+12V Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
39h
+1.5V_ICH Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
3ah
+1.1V_IOH Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
3bh
+5VSB Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
3ch VBAT
Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
3dh
P1VTT Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
3eh
+1.5V_P1DDR3 Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
3fh P2VTT
Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
40h
+3.3VSB Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
41h
+1.5V_P2DDR3 Voltage
02h Threshold
(01h)
UC, UNC, LC, LNC
UC,
LC
4Fh
Chassis Intrusion
Discrete (6Fh)
01h: General Chassis Intrusion,
02h: Drive Bay Intrusion