![Intel SC5650-DP Service Manual Download Page 36](http://html1.mh-extra.com/html/intel/sc5650-dp/sc5650-dp_service-manual_2071512036.webp)
Hardware Installations and Upgrades
18
Intel
®
Chassis SC5650-DP/WS/BRP/UP Service Guide
Installing the Front Bezel Assembly
1. Line up the three clips on the right side of the front bezel assembly with the
corresponding slots on the right side of the chassis (see letter “A” in the following
figure). Engage the clips with the slots (see letter “B”). Rotate the left side of the front
bezel assembly towards the chassis (see letter “C”). Snap the two bezel tabs into the
corresponding recesses at the left edge of the chassis front panel (see letter “D”).
Figure 14. Installing the Front Bezel Assembly (DP/WS/BRP configuration shown)
2. Reinstall the left side cover. For instructions, see
“Installing the Left Side Cover”
.
3. Reconnect all peripheral devices and the AC power cable. Power up the server.
Installing or Removing a Server Board
Note: The type of Intel
®
Server Board you can install in your chassis depends on the model of
chassis you purchased. For a breakout of server board/chassis model compatibility, see
Table 1, “Breakdown of Intel® Server Chassis SC5650 Configurations”
.
To install or remove a server board, do the following:
1. Observe the safety and ESD precautions listed in
Appendix A, “Safety Information”
.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see
“Removing the Left Side Cover”
4. Remove the front bezel assembly. For instructions, see
TP02035
D
D
A
A
A
C
A
B
Summary of Contents for SC5650-DP
Page 8: ...Preface viii Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 16: ...xvi Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 18: ...xviii Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 30: ...Server Chassis Features 12 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 78: ...Hardware Installations and Upgrades 60 Intel Chassis SC5650 DP WS BRP UP Service Guide...
Page 116: ...Technical Reference 98 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 137: ...Intel Server Chassis SC5650 DP WS BRP UP Service Guide 119...
Page 138: ...120 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 139: ...Intel Server Chassis SC5650 DP WS BRP UP Service Guide 121...
Page 140: ...122 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 141: ...Intel Server Chassis SC5650 DP WS BRP UP Service Guide 123...
Page 142: ...124 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 154: ...136 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 156: ...Getting Help 138 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 164: ...Warranty 146 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...
Page 174: ...156 Intel Server Chassis SC5650 DP WS BRP UP Service Guide...