On-board Connector/Header Overview
Intel® Server Board S2600CO Family TPS
Revision
1.4
Intel order number G42278-004
86
Color State Criticality
Description
supply configuration was present.
Unable to use all of the installed memory (one or more DIMMs
failed/disabled but functional memory remains available)
Correctable Errors over a threshold and migrating to a spare
DIMM (memory sparing). This indicates that the user no longer
has spared DIMMs indicating a redundancy lost condition.
Corresponding DIMM LED lit.
Uncorrectable memory error has occurred in memory Mirroring
Mode, causing Loss of Redundancy.
Correctable memory error threshold has been reached for a
failing DDR3 DIMM when the system is operating in fully
redundant RAS Mirroring Mode.
Battery
failure.
BMC executing in uBoot. (Indicated by Chassis ID blinking at
Blinking at 3Hz). System in degraded state (no manageability).
BMC uBoot is running but has not transferred control to BMC
Linux*. Server will be in this state 6-8 seconds after BMC reset
while it pulls the Linux* image into flash
BMC booting Linux*. (Indicated by Chassis ID solid ON).
System in degraded state (no manageability). Control has been
passed from BMC uBoot to BMC Linux* itself. It will be in this
state for ~10-~20 seconds.
BMC Watchdog has reset the BMC.
Power Unit sensor offset for configuration error is asserted.
HDD HSC is off-line or degraded.
Amber
~1 Hz blink
Non-critical -
System is
operating in a
degraded state
with an impending
failure warning,
although still
functioning
Non-fatal alarm – system is likely to fail:
Critical threshold crossed – Voltage, temperature (including
HSBP temp), input power to power supply, output current for
main power rail from power supply and PROCHOT (Therm Ctrl)
sensors.
VRD Hot asserted.
Minimum number of fans to cool the system not present or failed
Hard drive fault
Power Unit Redundancy sensor – Insufficient resources offset
(indicates not enough power supplies present)
In non-sparing and non-mirroring mode if the threshold of
correctable errors is crossed within the window
Correctable memory error threshold has been reached for a
failing DDR3 DIMM when the system is operating in a non-
redundant mode
Amber Solid
on Critical,
non-
recoverable –
System is halted
Fatal alarm – system has failed or shutdown:
CPU CATERR signal asserted
MSID mismatch detected (CATERR also asserts for this case).
CPU 1 is missing
CPU Thermal Trip
No power good – power fault
DIMM failure when there is only 1 DIMM present and hence no
good memory present1.
Runtime memory uncorrectable error in non-redundant mode.
DIMM Thermal Trip or equivalent
SSB Thermal Trip or equivalent
CPU ERR2 signal asserted
BMC\Video memory test failed. (Chassis ID shows blue/solid-on
for this condition)
Summary of Contents for S2600CO series
Page 12: ......