Appendix D: Intel® Server Board S2600CO Family Specific Sensors
Intel® Server Board S2600CO Family TPS
Revision
1.4
Intel order number G42278-004
134
Hot-plug fan support
Supported on:
Intel
®
Server Chassis P4208 (UPM with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPM with redundant fan 4U)
Intel
®
Server Chassis P4308 (UPM with redundant fan 4U)
Fan redundancy support
Supported on:
Intel
®
Server Chassis P4208 (UPM with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPM with redundant fan 4U)
Intel
®
Server Chassis P4308 (UPM with redundant fan 4U)
Table 71. Fan Domain Definition
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P4208/P4216/P4304/P4308
(UPM with fixed fan
4U/general SKU)
0
SSB
Temp
(22h)
BB BMC Temp (23h)
BB MEM VR Temp (25h)
HSBP 1 Temp (29h)
HSBP 2 Temp (2Ah)
Exit Air Temp (2Eh)
LAN NIC Temp (2Fh)
DIMM Thrm Mrgn 2 (B1h)
DIMM Thrm Mrgn 3 (B2h)
System Fan 1 (30h)
1
BB P2 VR Temp (24h)
BB MEM VR Temp (25h)
HSBP 1 Temp (29h)
HSBP 2 Temp (2Ah)
Exit Air Temp (2Eh)
P1 Therm Margin (74h)
P2 Therm Margin (75h)
DIMM Thrm Mrgn 1 (B0h)
DIMM Thrm Mrgn 2 (B1h)
DIMM Thrm Mrgn 3 (B2h)
DIMM Thrm Mrgn 4 (B3h)
System Fan 2 (31h)
P4208/P4216/P4308 (UPM
with fixed fan 4U/150W SKU)
0
SSB
Temp
(22h)
BB BMC Temp (23h)
BB MEM VR Temp (25h)
HSBP 1 Temp (29h)
HSBP 2 Temp (2Ah)
Exit Air Temp (2Eh)
LAN NIC Temp (2Fh)
DIMM Thrm Mrgn 2 (B1h)
DIMM Thrm Mrgn 3 (B2h)
System Fan 1 (30h)
1
BB P2 VR Temp (24h)
BB MEM VR Temp (25h)
System Fan 2 (31h)
Summary of Contents for S2600CO series
Page 12: ......